Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Node
  3. How To Close HDLC Mode E?

How to close HDLC Mode E?

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Jeroen88 , 21 April, 2021
Forums
Gurux.DLMS

Hi Mikko,

If a meter uses IEC62056-21 Mode E as starting protocol, after sending <ACK> '2' 'Z' '2' <CR> <LF> the meter accepts HDLC commands. But what if I want to return to before Mode E? If you want to return from Mode C you can send a break (<SOH> 'B' '0' <ETX> <BCC>), but what is the Mode E equivalent?

Best Jeroen

Profile picture for user Kurumi

Kurumi

5 years 5 months ago

Hi,

Hi,

Meter is returning from Mode E when the HDLC Disconnect message is sent to the meter.

BR,
Mikko

Jeroen88

5 years 5 months ago

Even if a connect message is

Even if a connect message is not yet sent?

Profile picture for user Kurumi

Kurumi

5 years 5 months ago

Hi,

Hi,

You can force to send disconnect message setting force parameter to true:

GXDLMSClient.DisconnectRequest(true);

Otherwise, the disconnect is sent only when a client has established a connection to the meter.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • abuw.01
  • Anaglyfos Trading CC
  • cyby
  • Metin Onan
  • ssv007
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin