By Jeroen88 , 21 April, 2021
Forums
Gurux.DLMS

Hi Mikko,

If a meter uses IEC62056-21 Mode E as starting protocol, after sending <ACK> '2' 'Z' '2' <CR> <LF> the meter accepts HDLC commands. But what if I want to return to before Mode E? If you want to return from Mode C you can send a break (<SOH> 'B' '0' <ETX> <BCC>), but what is the Mode E equivalent?

Best Jeroen

Profile picture for user Kurumi

Kurumi

5 years 3 months ago

Hi,

Hi,

Meter is returning from Mode E when the HDLC Disconnect message is sent to the meter.

BR,
Mikko

Jeroen88

5 years 3 months ago

Even if a connect message is

Even if a connect message is not yet sent?

Profile picture for user Kurumi

Kurumi

5 years 3 months ago

Hi,

Hi,

You can force to send disconnect message setting force parameter to true:

GXDLMSClient.DisconnectRequest(true);

Otherwise, the disconnect is sent only when a client has established a connection to the meter.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More

Who's new

  • agize
  • BioTips
  • Vital479
  • HealthPro16
  • Brandondiz
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin