Hi,

I want to change capture objects into the Load Profile channel 1.1.99.1.0.255 in a meter.

In the meter document it says "Load Profile logger, Attr1 = 1.1.99.1.0.255, Attr 2-3 Access Read, Attr 4 Access ReadWrite, Attr 5-8 Access Read.

So in the light of this, I believe that I can write capture objects with Attr Index 4.

However,

var profileGeneric = new GXDLMSProfileGeneric("1.1.99.1.0.255");
var captureObject = new GXDLMSCaptureObject(4, 0);
profileGeneric.CaptureObjects.Add(new GXKeyValuePair<GXDLMSObject, GXDLMSCaptureObject>(new GXDLMSRegister("1.1.1.8.0.255"), captureObject));

var reply = new GXReplyData();
DlmsReader.ReadDataBlock(dlmsClient.Write(profileGeneric, 3), reply);

throws access denied exception.

I can set the clock with;

DlmsReader.ReadDataBlock(DlmsSettings.Client.Write(clock, 2), reply);

So am I doing something wrong? My data index and attr index is true?

Profile picture for user Kurumi

Kurumi

5 years 5 months ago

Hi,

Hi,

There are only three attributes in the register-object and you have set attribute #4. Check that.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Version mismatch between Gurux.DLMS 9.x and Gurux.Common/Gurux.Serial 8.x
  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
More

Who's new

  • Anas Zaatreh
  • QDeYZLrphMziQF…
  • sharrongm69
  • agize
  • BioTips
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin