GXDLMSDirector CTT issue

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By rajacms , 26 February, 2021
Forums
General discussion

Dear Mikko,
GXDLMSDirector issue for CTT testing - please check it
it is showing - Object reference not set to an instance of an object.

10:47:11 Send SNRM request.
TX: 7E A0 07 03 21 93 0F 01 7E
10:47:11
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
10:47:11
Object reference not set to an instance of an object.
10:47:11 Disconnect request
TX: 7E A0 07 03 21 53 03 C7 7E
10:47:11
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

Profile picture for user Kurumi

Kurumi

5 years 5 months ago

Hi,

Hi,

What test is causing this?

BR,
Mikko

rajacms

5 years 5 months ago

Dear Mikko,

Dear Mikko,

when i start running GXDLMSDirector->CTT it will coming like that. previous version not given this issue

Starting to execute test for PC.
Object reference not set to an instance of an object.System.NullReferenceException: Object reference not set to an instance of an object.
at GXDLMSDirector.GXDLMSCommunicator.InitializeConnection(Boolean force)
at GXDLMSDirector.GXConformanceTests.ReadXmlMeter(Object data)

Profile picture for user Kurumi

Kurumi

5 years 5 months ago

Hi,

Hi,

I can repeat the issue. I created an issue from this.
https://www.gurux.fi/node/17980

This is fixed ASAP.

BR,
Mikko

Profile picture for user Kurumi

Kurumi

5 years 5 months ago

Hi,

Hi,

This is fixed and a new version is released.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More

Who's new

  • CTKNhZElptjSlOrpkXl
  • YCbccqfLGRMnlCWoJhXP
  • Malcolmactig
  • mhliang
  • Kevinmug
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin