  2. Query Related To IEC62056-21 Mode E Support

Query related to IEC62056-21 mode E support

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By nipam.bhavsar , 11 September, 2020
Forums
DLMSDirector

Hello GuruX Team,

Greetings !!!

We are currently working on our own custom meter and testing with DLMSDirector software. Our custom meter is having support of IEC62056-21 optical port mode E and want to test with DLMSDirector software.

We tried to test this feature with software but we are not able to get any response from this software. We have selected IEC protocol as start protocol. For mode E, our custom meter is supported 300 baud rate as default and then it will convert to 4800 baud rate. For mode E, our meter is supported Device ID and Identification string to communicate but this kind of setting is not able to find in software. As our meter is custom made so we can change these parameters according to DLMSDirector software procedure.

Can you please help us on how to configure mode E protocol in DLMSDIrector software?

Attached pictures are for your reference that shows settings that we have done in DLMSDirector software. Please let me know if you need any further information.

Have a Good Day !!!

Thanks & Regards,
Nipam

Image
Profile picture for user Kurumi

Kurumi

5 years 9 months ago

Hi Nipam,

Hi Nipam,

Mode E is not a configurable feature. It's defined in IEC 62056-21 and not in IEC 62056-46 so it might be that your meter simply doesn't support this feature.

If you send /?!\r\n as ASCII string and the meter doesn't reply anything Mode E is not implemented in your stack.

BR,
Mikko

nipam.bhavsar

5 years 9 months ago

In reply to Hi Nipam, by Kurumi

Dear Mikko,

Dear Mikko,
Thanks for your response. We will check our end and will update you.

Thanks,
Nipam

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin