By nishitha , 8 July, 2020
Forums
Gurux DLMS for Java

hi Mikko,
I see that in DLMS Server code whenever the client sends data onReceived function is called, in my case client will send data until display is ON, so till then rx, tx is working fine, then later i am closing the program from the stop operation in Intellij instead I want to close server, so i wrote close(); function inside onreceived() function, but sevrer got closed after the first RX only, is there a way to stop server after client stops sending data?

Profile picture for user Kurumi

Kurumi

6 years 2 months ago

Hi,

Hi,

The meter must reply for a disconnect message so you can't close it right away. Basically you can wait for a Disconnected event and then close the connection after you have sent the reply in the OnReceived method.

How you are planning to restart the server after it's closed?

nishitha

6 years 2 months ago

Hi Mikko,

Hi Mikko,
I have UI which sends data to server, but i got the solution to close server and after that i dont want to open it,

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
  • dw772
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin