Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Decoding AARQ Packet

decoding AARQ packet

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By jan.kolar , 9 January, 2020
Forums
Gurux.DLMS

Dear Mikko,

could you please help me decoding these AARQ packet ? I am able to decode header up to byte 0x60 which indicates AARQ. 0x53 is probably length. I am not able to go further. I know your online decoder but I want to decode bits manually. It is sufficient if you decode first two fields which should be ProtocolVersion and ApplicationContextName. I want to know meaning of every bit. I have problem connecting to meter with High level security. Using manufacturer software is no problem. Using Gurux library meter responds with error in AARE. We have DLSM/COSEM standard but unfortunately it is very complicated. I dont know where to find needed info. It contains some example AARQ packets, but I am not able to apply these examples to my case below. Thank you.

7e a0 61 03 61 10 84 23 e6 e6 00 60 53 80 02 07
80 a1 09 06 07 60 85 74 05 08 01 02 a6 0a 04 08
4c 47 5a 4d 41 50 00 00 8a 02 07 80 8b 07 60 85
74 05 08 02 06 ac 18 80 16 27 61 53 6b 3d 36 2d
66 3e 49 21 67 5a 62 66 58 3b 38 36 41 2c 44 be
0f 04 0d 01 00 00 00 06 5f 04 00 1c 13 20 00 00
9a 98 7e

Profile picture for user Kurumi

Kurumi

6 years 6 months ago

Hi,

Hi,

I'm afraid that it's not so easy. Is this AARQ from the app that you are using to read the meter?

The problem with AARQ is that if one of the bits is wrong meter doesn't accept the connection.
So if you have set one property wrong, the meter might reject the connection.

I can help you to find the correct settings.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Version mismatch between Gurux.DLMS 9.x and Gurux.Common/Gurux.Serial 8.x
  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
More

Who's new

  • Duaneduh
  • ClaytonPap
  • sAYgntkdaTjhgpvfz
  • HenryEneno
  • ScottCab
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin