By pradson , 4 November, 2019
Forums
Gurux.DLMS

Hi Mikko,

How to read ice hdlc setup obis object using c++?
Kindly share me a sample code.

Like this-
//-------------------------------------------------------------------
CGXDLMSRegister *iecHdlcObj = new CGXDLMSRegister("0.0.22.0.0.255");
std::string sValue;
if ((ret = comm.Read(iecHdlcObj, 8, sValue)) != 0)
{
TRACE("err! failed to read register: %s", CGXDLMSConverter::GetErrorMessage(ret));
}
//-------------------------------------------------------------------

The above mentioned code is not working and showing the error-
err! failed to read register: Access Error : Device reports a inconsistent Class or Object.

Kindly suggest.

Thanks & Regards,
Pradson

Profile picture for user Kurumi

Kurumi

7 years ago

Hi,

Hi,

std::string sValue;
CGXDLMSIecHdlcSetup iecHdlcObj("0.0.22.0.0.255");
comm.Read(&iecHdlcObj, 8, sValue);

BR,
Mikko

pradson

7 years ago

In reply to Hi, by Kurumi

Thanks a lot Mikko.

Thanks a lot Mikko.

Actually, silly mistake was in my side that the file was not included that's why the object "CGXDLMSIecHdlcSetup" was not appearing.

Thanks & Regards,
Pradson

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Landis E650 meter reading over DLMS
  • class_id = 40, version = 2, pushsetup Unparsed data frame
  • GXObisValueItem entries without MaskSize appear to be interpreted as bit flags
  • CheckedListBox incorrectly selects GXObisValueItem Value=0 for non-zero values
  • UIValueType=TextBox is rendered as CheckedListBox when Values are defined
More

Who's new

  • Sayang
  • q80435762@gmail.com
  • ONCAK
  • Berhasil
  • ratirvivege1979
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin