class_id = 40, version = 2, pushsetup Unparsed data frame
00280000190900FF0200*0107020612002809060000190900FF0F0212000002021600000100020612000109060000600586FF0F02120000020216000001000206120001090600002A0000FF0F0212000002021600000100020612000109060000600100FF0F0212000002021600000100020612000109060000616200FF0F021200000202160000010002061200010906000061620AFF0F0212000002021600000100020612000109060000600587FF0F0212000002021600000100;
00280000190900FF0400*0100
Hi, Can you add the complete…
Hi,
Can you add the complete PDU so I can check it?
BR,
Mikko
The following message…
The following message appears on the interface:
You need to read Association view to see all objects what the meter can offer. Do you want to do it now?
Click Yes, then read all objects (OBIS=0-0:40.0.0.255, att=2). After the read completes, the Push Setup view on the interface cannot be displayed.
Previously, with class_id = 40, version = 0, the interface displayed normally; now with version = 2, it does not display properly. Is it because the current tool does not support parsing the data objects under class_id = 40, version = 2?
The data volume is too large, so only a small relevant segment was extracted.
Duration: 254
15:54:41 Get next frame.
15:54:41 Collecting objects
7E A0 07 03 23 31 A7 B4 7E
<HDLC len="9" >
<TargetAddress Value="1" />
<SourceAddress Value="11" />
<FrameType Value="31" />
<Command Value="NextFrame" />
</HDLC>
15:54:42
7E A0 7C 23 03 92 6E 99 01 00 02 03 0F 02 16 01 00 02 03 0F 03 16 01 00 02 03 0F 04 16 01 00 02 03 0F 05 16 01 00 02 03 0F 06 16 03 00 01 01 02 02 0F 01 16 01 02 04 12 00 28 11 02 09 06 00 00 19 09 00 FF 02 02 01 07 02 03 0F 01 16 01 00 02 03 0F 02 16 03 00 02 03 0F 03 16 03 00 02 03 0F 04 16 01 00 02 03 0F 05 16 03 00 02 03 0F 06 16 03 00 02 03 0F 07 16 03 00 01 00 52 65 7E
<HDLC len="7B" >
<TargetAddress Value="11" />
<SourceAddress Value="1" />
<FrameType Value="92" />
<NextFrame Value="010002030F0216010002030F0316010002030F0416010002030F0516010002030F06160300010102020F0116010204120028110209060000190900FF0202010702030F0116010002030F0216030002030F0316030002030F0416010002030F0516030002030F0616030002030F071603000100" />
</HDLC>
Hi, The version doesn't…
Hi,
The version doesn't affect this, and customers are already using version 2. If you get this error when you try to read the association view, the reason is in your association view. You need to check it.
Regards,
Mikko
For Push setup with class_id…
For Push setup with class_id = 40, version = 0 / version = 1 / version = 2:
I’m not sure how you handle the Push setup interface, so I ran a test.
Under all three versions, only Attribute=1 is supported, and at this point it does not involve any data. However, the Push setup interface for version = 0 can parse and display normally, whereas the Push setup interfaces for version = 1 and version = 2 both display errors.