Samgas check status

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Ruggero Quargentan , 12 January, 2017
Forums
Gurux.Serial

Hello, i'm not able to have answer from a samgas without setting up comunication
in the device.
What does it mean checking status ?
What is the function that i can use ?
Thanks

Profile picture for user Kurumi

Kurumi

9 years 5 months ago

Samgas check status

Hello,

Press Green button. Then move to SD. Values should be 01 01 01.
If they are, change as described on the manual.

BR,

Mikko

Ruggero Quargentan

9 years 5 months ago

In reply to Samgas check status by Kurumi

Hello, i know this procedure

Hello, i know this procedure and it works.
I need to know if there is a way with the infrared probe to do this.
Do you know if there is a wake up sequence to send ?
thanks .

Profile picture for user Kurumi

Kurumi

9 years 4 months ago

Samgas

Hi,
We are using infrared probe. Just connect optical probe and check status as described.
Then you can read your meter.

BR,

Mikko

murox23

8 years 9 months ago

Good morning;

Good morning;
i add a new post here because i'd like to know if there is some "work around" in order to keep alive the optical port without every time go phisically in front of meter just for "power on" the display going under SD status.
I ask this because i need to read data from meter periodically with a SCADA software that's disclocated in other area respect the meter.

If have any suggestion or also if there isn't possibility to do this please reply anyway at this answer.

Many Thanks in advance!
Have a nice day

Marco M.

Profile picture for user Kurumi

Kurumi

8 years 9 months ago

In reply to Good morning; by murox23

Samgas check status

Hi,

Please, create own topic if you have new question.
If you are not reading your meter continually try send keep alive message every 30 second (about).
It might keep connection up. Remember that this is using battery.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin