Hi,
We've got a Itron SL7000 meter. We need to read
Active Energy Aggregate: 1.1.1.29.0.255 data. But there is no obis code ace.xml manufacturer doc. Is there any way to add this obis code to manufacturer settings.
load profile 0.0.99.1.0.255 is waiting long time and we can not get anything.
You not need to add this info to xml. Just make connection to the meter and read Association View (Select Refresf from File menu). It will read available objects from the meter.
If you see only one object, reason is that you are using None -Authentication mode. Change authentication to Low and you can get larger list of objects.
Itron SL7000 read profile data problem
Hi,
You not need to add this info to xml. Just make connection to the meter and read Association View (Select Refresf from File menu). It will read available objects from the meter.
If you see only one object, reason is that you are using None -Authentication mode. Change authentication to Low and you can get larger list of objects.
BR,
Mikko