Hello, I'm trying to read data from meter ITRON SL7000 Type SL761B071 using RS232 connection and DLSM Protocol.
I'm able to get only two datas using GXDirector, under the label "DATA" of my Device, I'm able to read only 0.0.42.0.0.255 COSEM Logical Device Name, and under the label "Association Logical Name" of my Device, I'm able to read only 0.0.40.0.16.255 Ch.0 Association #16.
What am I doing wrong? Should I view more informations under the label "DATA"?
The device is connected (I think), althogh I would not be able to get any information...

Thank you for your replay

Profile picture for user Kurumi

Kurumi

11 years 5 months ago

Reading data from SL7000

Hi,

You are reading your meter with authentication level None.
Change authentication level to Low. Default password is ABCDEFGH.

BR,

Mikko

Mrk89

11 years 5 months ago

Hi Mikko, thank you for your

Hi Mikko,
thank you for your fast reply.
I'm going to try this solution as soon as possible.
I will tell you if I succeed in or not.

Have a good day

Mrk89

11 years 5 months ago

In reply to Reading data from SL7000 by Kurumi

Another problem...

Hello Mikko,
I tried to read my meter using the authentication password, but I get another error...
I think password is correct, because if I put in a wrong password I get an authentication error.
I get a pop up message saying "Access Error: Device reports scope of access violated."
Sorry but I dont really know what this message means...

Thank you for your reply

Profile picture for user Kurumi

Kurumi

11 years 5 months ago

Hi Mikko, thank you for your

Hi,

This meter is older meter and Actaris has not implement all functionality.
This error simple means that this is not implemented. :-)
There are some other strange things as well. :-(

Id this happens with our products (GXDLMSDirector, Gurux.DeviceSuite), let me know.

BR,

Mikko

Mrk89

11 years 5 months ago

In reply to Hi Mikko, thank you for your by Kurumi

Hi, I get this problems using

Hi,
I get this problems using GXDLMSDirector.
Probably there are different obis codes? For example when I read variables manually (using the meter buttons) I can read 1.1.2.8.0 obis code on the meter's display and this is not in the list of actaris obis codes (I found 1.1.2.8.0.255 but I think it's different).
Should I try to create new manufacturer settings and then add my obis code?
Or is there any other way to read the meters?

Thank you

Profile picture for user Kurumi

Kurumi

11 years 5 months ago

Reading data from SL7000

Hi,

Can you send your trace to me?
You can get log file from Tools menu.

Do following:

1. Make connection.
2. Select Refresh from tools menu.
3. Read item that causes this error.
4. Send log to me.

We will check this after Christmas.

BR,

Mikko

Mrk89

11 years 5 months ago

In reply to Reading data from SL7000 by Kurumi

Hi Mikko, I will try what you

Hi Mikko,
I will try what you wrote to me as soon as possible, the meter is 50 km far from me.
Merry christmas for now, have a good day and thank you.

Marco

movie_maniac

11 years 1 month ago

Trying to access the same meter

Just to understand if I have understood :)

Manufacturer: Actaris Electricity
Protocol: DLMS
Media: Serial
Autentication: Low
Logical name referencing: Yes
password: ABCDEFGH
Wait time: 5
Client address: 1
Address type: default
Physical server: 11
Logical server: 1
Serial port: My COM PORT

Is everything right?
Meter is SL761B071 built in 2008

Thanks

Profile picture for user Kurumi

Kurumi

11 years ago

Reading data from SL7000

Hi,

Sorry I miss your post.

There are two different versions from this meter.
Your one is supporting DLMS.

Your settings seems to be right, so you should be able to read your meter with default settings.

BR,

Mikko

cgonzalezb

10 years 11 months ago

In reply to Trying to access the same meter by movie_maniac

Got the same problem

Did you fix it?

Profile picture for user Kurumi

Kurumi

10 years 10 months ago

SL 7000

Hi,

You can read SL 7000 using GXDLMSDirector.

With profile generics (historical data) there are some
issues because data is not DLMS compatible.

Br,

Mikko

ooni

8 years ago

Problem communicating with Itron SL7000

Hi
I am trying to communicate with an Itron SL7000 meter but I am struggling to get any data out of the RS232 serial port. I have looked at both RJ45 connectors TX=pin5 and GND=pin6.

The pin reference were taken from the "Installation Guide SL7000 RT" Page 29: http://www.integra.co.it/wp-content/uploads/2017/11/SL7000-RT-Installat…
Is there anything that has to happen before the meter starts spewing out data?
I currently using an Oscilloscope to see if there is any data on serial port before validating the contents of the data.
Any help would be appreciated. Many thanks

Profile picture for user Kurumi

Kurumi

8 years ago

Problem communicating with Itron SL7000

Hi ooni,

Please make a new thread if you have new questions.

Are you getting any reply from the meter? Note that there is two version from SL7000. One is supporting DLMS and another is not.

https://www.gurux.fi/node/4064

BR,

Mikko

Yassine ilkaghene

6 years 3 months ago

Hi every body. I'm new in the

Hi every body. I'm new in the forum. Please can i get the database of regesters on SL7000
Regrads
[Email address removed by Administrator]

Profile picture for user Kurumi

Kurumi

6 years 3 months ago

In reply to Hi every body. I'm new in the by Yassine ilkaghene

Hi Yassine,

Hi Yassine,
Please, create a new topic if you have a new question. I'll answer your question there.

BR,
Mikko

Syakir

5 years 6 months ago

Hi Mikko, for ITRON SL7000,

Hi Mikko, for ITRON SL7000, Im confuse about its connection. Im using RS485, does this connection correct ? :

From Itron use only RX + and RX - ?

Profile picture for user Kurumi

Kurumi

5 years 6 months ago

In reply to Hi Mikko, for ITRON SL7000, by Syakir

Hi Akir,

Hi Akir,
Please, create a new topic if you have a new question. I'll answer your question there.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin