Getting Issue while updating Meter sim number

By muhammad ahmed , 22 August, 2024
Forums
General discussion

I'm encountering an issue while updating SIM numbers. Below is the hex command I use to retrieve the SIM numbers:
00 01 00 11 00 01 00 22 C0 03 81 03 00 01 00 00 80 BE 01 FF 02 00 00 01 00 00 80 BE 02 FF 02 00 00 01 00 00 80 BE 03 FF 02 00

I created the following request to update the SIM numbers:

00 01 00 11 00 01 00 4A C1 04 81 03 00 01 00 00 80 BE 01 FF 02 00 00 01 00 00 80 BE 02 FF 02 00 00 01 00 00 80 BE 03 FF 02 00 03 0A 0B 30 33 32 32 34 36 34 34 34 34 33 0A 0B 30 33 32 32 34 36 37 38 38 38 33 0A 0B 30 33 32 32 34 36 37 35 35 35 33

However, when I send this hex command, the response I receive from the meter is:

0001000100110001C1 I'm not sure what this response means.

I then tried to update the SIM numbers using this command:
00 01 00 11 00 01 00 73 C3 01 41 00 12 00 00 2C 00 01 FF 02 01 02 02 06 00 00 00 00 09 5D 32 34 2D 30 38 2D 32 32 30 31 3A 31 38 3A 31 36 00 03 00 17 00 01 00 00 80 BE 01 FF 02 C1 0A 0B 30 33 33 35 34 34 34 35 31 33 39 00 17 00 01 00 00 80 BE 02 FF 02 C1 0A 0B 30 33 33 35 34 34 34 35 31 33 39 00 17 00 01 00 00 80 BE 03 FF 02 C1 0A 0B 30 33 33 30 30 30 30 30 30 30 30

This time, the response from the meter indicated confirmation and success, but when I fetched the numbers again, they were not updated. What could be the issue?

Profile picture for user Kurumi

Kurumi

1 year 11 months ago

Hi, 0001000100110001C1 is…

Hi,

0001000100110001C1 is invalid reply. There is something wrong with the meter.

In the second attempt, you will try to update the image. You need to ask the meter manufacturer what object you need to use to update the SIM number.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin