Hi.

When i read a Profile Generic for the first time through API /api/Task/Add, I do not want to read all the values in the meter.

How can i tell it to get values from date a to date b?

I normally send it like:

{
"Tasks": [
{
"Order": 1,
"Batch": "DC74A838-ADCA-4B6A-B633-AB3E870A2188",
"Object": {
"Id": "E18D57DC-6872-4B69-858C-05848B5585FB"
},
"TaskType": 1
}
]
}

Profile picture for user Kurumi

Kurumi

1 year 10 months ago

Hi, All historical (profile…

Hi,

All historical (profile generic) values are read from the meter and stored in the database. So after they are read once, the historical values are retrieved from the database and not from the meter.

If you don't want to read all values from the beginning, you can set the buffer read time of the profile generic and the values will be read after that.

thiesens

1 year 10 months ago

Hi again. How do i set the…

Hi again.

How do i set the buffer read time?

Do I just:

Get the attribute value with /api/Attribute?id=*******

and send the starttime in via /api/Attribute/Update?

Profile picture for user Kurumi

Kurumi

1 year 10 months ago

Hi, Yes, do it exactly like…

Hi,

Yes, do it exactly like that.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 02/19/2026 - 11:51
    gurux.dlms.cpp 9.0.2602.1901
  • Sun, 02/01/2026 - 19:47
    gurux.dlms.cpp 9.0.2602.0101
  • Tue, 01/20/2026 - 10:38
    gurux.dlms.java 4.0.89
  • Wed, 01/14/2026 - 14:29
    Gurux.DLMS.Python 1.0.196
  • Mon, 12/29/2025 - 10:38
    Gurux.Serial.Android 3.0.5

New forum topics

  • Help with connection and read with landis+gyr e650 + CU-E22 using python
  • Preestablished connection
  • RJ11 to RS232 Pin out SECURE Premier 300
  • GENUS sugam 3 PH bidirectional
  • Electricity smart Meter DLMS firmware stack
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin