Image update server fails

By KostaG , 22 February, 2024
Forums
General discussion

Hi,

I'm implementing the image update in my meter. When I send the binary through GXDLMSDirector, I get the "UnacceptableFrame" error message after ActionRequest of method 2.

Any idea of where my problem could probably be?

Thank you,

Regards.

KostaG

2 years 5 months ago

I forgot to mention, my…

I forgot to mention, my server is written in ANSI C and I also have defined DLMS_IGNORE_MALLOC.

Profile picture for user Kurumi

Kurumi

2 years 5 months ago

Hi, Is this error coming…

Hi,

Is this error coming when you are transferring the Image or in verification or activation? Make sure that the Image block size is smaller than the PDU size. This is usually the reason.

https://www.gurux.fi/Gurux.DLMS.Objects.GXDLMSImageTransfer

BR,
Mikko

KostaG

2 years 5 months ago

It is comming while…

It is comming while transferring the first block of the Image. I checked the Image block size and it is smaller than the max PDU size.

Profile picture for user Kurumi

Kurumi

2 years 4 months ago

Hi, Did you handle the…

Hi,

Did you handle the received image block in pre_action? You need to set handled to true like this:

e->handled = 1;

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin