Hi!

I live in Finland and I have Echelon 83332 meter. Seems that I'm receiving push messages from the device's optical port (ttyUSB0).

However I have no idea how to parse those messages. I'm looking for a way to read real-time energy consumption.

Any help would be highly appreciated. Is decryption key required in Finland? Operator is Caruna.

Profile picture for user Kurumi

Kurumi

3 years 5 months ago

Hi,

Hi,

If you add a received push message as a hex string so I can check if the push message is sent as DLMS and what are the settings.

BR,
Mikko

ape

3 years 5 months ago

Hi Mikko,

Hi Mikko,

Thanks for such a quick reply!

Here's the output from Push Listener Example.

Push messages are sent/received every five seconds and split to two rows.

```
gurux_dlms version: 1.0.139
gurux_net version: 1.0.19
gurux_serial version: 1.0.20
/dev/ttyUSB0:9600 8NONE1
Press any key to close the application.
Media state changed. MediaState.OPENING
trace:10:23:23 TraceTypes.INFO Settings: Port: /dev/ttyUSB0 Baud Rate: BaudRate.BAUD_RATE_9600 Data Bits: 8 Parity: Parity.NONE Stop Bits: StopBits.ONE Eop:126
Media state changed. MediaState.OPEN
New data is received. /dev/ttyUSB0:00 59 00 00 4E 00 00 00 00 00 00
New data is received. /dev/ttyUSB0:00 00 61 B8 7B 0B 00 01 00 00 00 00 00 00 00 03 00 00 00 00 08 00 00 00 00 00 00 00 E2 0A 00 00 00 09 00 00 00 00 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 00 00 00 0B 00 00 00 00 00 00 00 B1 00 00 00 00 E4 4F DF 51 22 22 E0 5C
New data is received. /dev/ttyUSB0:00 59 00 00 4E 00 00 00 00 00 00 00 00 65 B8
New data is received. /dev/ttyUSB0:7B 0B 00 01 00 00 00 00 00 00 00 03 00 00 00 00 08 00 00 00 00 00 00 00 E0 0A 00 00 00 09 00 00 00 00 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 00 00 00 0B 00 00 00 00 00 00 00 B3 00 00 00 00 15 91 A6 FF 07 A9 34 AF
New data is received. /dev/ttyUSB0:00 59 00 00 4E
New data is received. /dev/ttyUSB0:00 00 00 00 00 00 00 00 69 B8 7B 0B 00 01 00 00 00 00 00 00 00 03 00 00 00 00 08 00 00 00 00 00 00 00 E6 0A 00 00 00 09 00 00 00 00 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 00 00 00 0B 00 00 00 00 00 00 00 B1 00 00 00 00 F0 ED 7B C2 07 21 29 74
New data is received. /dev/ttyUSB0:00 59 00 00 4E 00 00 00 00 00 00 00 00 6D
New data is received. /dev/ttyUSB0:B8 7B 0B 00 01 00 00 00 00 00 00 00 03 00 00 00 00 08 00 00 00 00 00 00 00 FA 0A 00 00 00 09 00 00 00 00 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 00 00 00 0B 00 00 00 00 00 00 00 B1 00 00 00 00 BE 0A DD 9B 0E 0B F8 5F
```

Profile picture for user Kurumi

Kurumi

3 years 5 months ago

Hi,

Hi,

This doesn't look like any protocol that I know. I believe that your serial port settings are different than the meter uses.

Try to start the app with
python main.py -s /dev/ttyUSB0:B8:14400
OR
python main.py -s /dev/ttyUSB0:B8:19200
OR
python main.py -s /dev/ttyUSB0:B8:38400
OR
python main.py -s /dev/ttyUSB0:B8:56000
OR
python main.py -s /dev/ttyUSB0:B8:57600

The app is using different baud rates. You should see a message that starts with 7E. Your serial port settings are correct when you see that.

BR,
Mikko

ape

3 years 5 months ago

Many thanks for helping me

Many thanks for helping me out!

So far no luck with any of the mentioned serial port settings.

I also tried (and failed) Gurux.DLMS.Client.Example.python with the following output.

Maybe Finnish meters cannot be read?

```
$ python main.py -t Verbose -S /dev/ttyUSB0
gurux_dlms version: 1.0.139
gurux_net version: 1.0.19
gurux_serial version: 1.0.20
Authentication: Authentication.NONE
ClientAddress: 0x10
ServerAddress: 0x1
Standard: Standard.DLMS
TX: 19:31:15 7E A0 07 03 21 93 0F 01 7E
Data send failed. Try to resend 1/3
Data send failed. Try to resend 2/3
RX: 19:31:45 00 00 FF F0 F8 50 F6 FB 3C C8 15 FF F0 F8 50 F6 FB 3C 88 FC FF F0 F8 50 F6 FB 3C C8 15
DisconnectRequest
Traceback (most recent call last):
File "/home/pi/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/main.py", line 112, in main
reader.readAll(settings.outputFile)
File "/home/pi/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 532, in readAll
self.initializeConnection()
File "/home/pi/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 306, in initializeConnection
self.readDLMSPacket(data, reply)
File "/home/pi/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 118, in readDLMSPacket
self.readDLMSPacket2(data, reply)
File "/home/pi/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 169, in readDLMSPacket2
raise e
File "/home/pi/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 162, in readDLMSPacket2
raise TimeoutException("Failed to receive reply from the device in given time.")
gurux_common.TimeoutException.TimeoutException: Failed to receive reply from the device in given time.
Ended. Press any key to continue.
```

Profile picture for user Kurumi

Kurumi

3 years 5 months ago

Hi,

Hi,

If the meter sends push messages you don't establish the connection for the meter or read anything. You just wait for the data the meter sends.

I found 3 pcs of Echelon 83332 meters from the shelf. They are older and they don't send push messages and they don't use DLMS. I sent an email to Echelon and asked if the new firmware can be send so this can be tested.

A reply is usually coming in a few days. I'll inform you as soon as I have more information about this.

BR,
Mikko

ape

3 years 5 months ago

Thanks again. Amazing effort!

Thanks again. Amazing effort!

Just to let you know the exact model is Echelon 83332-3IHAH.

I contacted Caruna, my energy distribution company, and they were quite strict that optical port cannot be used by end customer. ¯\_(ツ)_/¯

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin