  3. Application Association Request: Device Reports An Unmatched Type

Application association request: Device reports an unmatched type

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By gardzielb , 19 December, 2022
Forums
Gurux DLMS for Java

Hi,

I am trying to connect with a meter using HLS GMAC. I update the frame counter, then I send SNRM request and parse response, then the same with AARQ request.

Finally, I try to send application association request with the following code:

reply.clear();
var associationRequest = client.getApplicationAssociationRequest();
for (byte[] it : associationRequest) {
readDLMSPacket(it, reply);
}
client.parseApplicationAssociationResponse(reply.getData());

I get an exception from readDLMSPacket stating "Device reports a unmatched type".
My application association request is the following:
-- Removed for privacy purposes --

What am I doing wrong?
I would appreciate any help, thank you.

Bartosz

Profile picture for user Kurumi

Kurumi

3 years 5 months ago

Hi,

Hi,

I believe that your block cipher or authentication key is different than the meter is using. Check that first.

BR,
Mikko

gardzielb

3 years 5 months ago

HI Mikko,

HI Mikko,

Thanks for your response. I am quite sure both of my keys are correct, because I can connect to the meter using dedicated manufacturer's software and passing the same keys.

I also tried connecting with your GXDLMSDirector and the result is the same: "Device reports unmatched type".

Regards,
Bartosz

Profile picture for user Kurumi

Kurumi

3 years 5 months ago

Hi,

Hi,

Then one of your settings is different from what the meter expects. There are lots of parameters in DLMS and if one is different the communication fails.

DLMS error codes don't tell much but check first the used authentication level.

If you can add a hex trace from the manufacturer message I can check that the used ciphering service is the same. There are multiple ways to transport the ciphered PDU and meters usually support only part of them.

BR,
Mikko

gardzielb

3 years 5 months ago

Hi,

Hi,

As far as I'm concerned the authentication level should be HIGH_GMAC with authenticated encryption. The log from manufacturer's software if the following:

-- Removed for privacy purposes --

If this is useful, I also send my log:

-- Removed for privacy purposes --

Thanks for your help.

Regards,
Bartosz

Profile picture for user Kurumi

Kurumi

3 years 5 months ago

Hi Bartosz,

Hi Bartosz,

The meter manufacturers' application is sending a challenge where authentication and encryption are marked and that is not correct because there is only an authentication tag.

300000014A44026FF690F23E71655A9E42

When Gurux application sends the challenge as it should be the meter returns UnmatchedType error. I believe that this is because the first byte is 0x10 and not 0x30.

100000014E57FF55736BB904AFFE6B6295

You need to ask the meter manufacturer if there is a firmware update available for the meter where this is fixed.

BR,
Mikko

gardzielb

3 years 5 months ago

Hi Mikko,

Hi Mikko,

Thank you very much for help, I'll contact the manufacturer.
I had to remove the logs from forum for the privacy purposes.

Best regards,
Bartosz

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin