  3. How To Read Hexing HXE116-kp Meter?

How to read Hexing HXE116-kp meter?

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

Profile picture for user hasan nasha
By hasan nasha , 24 October, 2022
Forums
General discussion

Hi.

I try to read and write data token from hexing HXE116-kp. I try manually in hercules serial using optical probe with HDLC mode E and get "/HXE5HX<CR><LF>".

And i try using GXDLMSDirector with hldc mode E, while meter trying to move baud rate, this meter cannot reply massage from software as i attached picture.

is here anyone here ever been able to read data from this meter? I still cannot find corrected setting including meter address. I cannot find manual from this meter and from vendor not given any clue about reading data from meter.

Another question, Is this meter not using DLMS?? I asked from vendor he telling this meter using DLMS. I think this meter not using DLMS because cannot found DLMS label from meter, and i suspect this meter using IEC62056-21 protocol.

Thanks

Image
Profile picture for user Kurumi

Kurumi

3 years 7 months ago

Hi,

Hi,

We have read HXE12 and that is supporting DLMS. All the documentation from the HXE116 shows that it's supporting only IEC62056-21 so I believe that you are right and your meter is not supporting DLMS.

You need to verify this from the meter vendor because it might be that there is the new firmware that supports DLMS, but I didn't find any information about it.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin