i am trying to write into my meter. i want to be able to recharge my meter via obis code. how do i go about it

vicfretz

4 years 2 months ago

recharging meters via obis

recharging meters via obis /dlms protocol

Profile picture for user Kurumi

Kurumi

4 years 2 months ago

Hi,

Hi,

You need to connect to the meter using a High authentication level. If the object's access rights is ReadWrite then you can write the value. Try to connect using GXDLMSDirector and try to write the value with that first. I believe it will help you to get an idea of how to write value for the DLMS meter.

BR,
Mikko

vicfretz

4 years 2 months ago

yes i understand the writing

yes i understand the writing proces but i want to know if it is possible to write a token for a prepaid meter access via dlms. i mean is it possible to recharge my meter via that writing process

Profile picture for user Kurumi

Kurumi

4 years 2 months ago

Hi,

Hi,

That depends on the meter. If the meter supports that and you have the access right for the meter it's possible.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Possible memory leak in file dlms.c, getCompactArrayItem(), getCompactArrayItem2()
  • Official Gurux.DLMS.Client.Example.Net fails during High GMAC secure association (Invalid PDU), while Gurux Director connects successfully
  • gurux_dlms.GXDateTime.GXDateTime object Error in Python
  • T_APPL_DATA_LN_N1 subtest 3 fails on an LN-only server regardless of the response to a non-existing-object GET
  • Version mismatch between Gurux.DLMS 9.x and Gurux.Common/Gurux.Serial 8.x
More

Who's new

  • RicardoNoula
  • ScottKit
  • liha_2019
  • FiqJXzPfbTtORWoZ
  • qZgCuGshgQLxtN…
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin