Hi,

Have followed ANSI C Client Example to read single object. But getting segmentation fault.
Please help.
gxData myobject;
cosem_init(&myobject.base,DLMS_OBJECT_TYPE_DATA,"0.0.96.1.0.255");
com_read(&con, &myobject.base, 2);
obj_toString(&myobject, &data); //Segmentation fault at this line

Below is the trace
TX: 7E A0 19 03 41 54 0A BB E6 E6 00 C0 01 81 00 01 00 00 60 01 00 FF 02 00 8C 6D 7E
RX: 7E A0 1A 41 03 74 DD 79 E6 E7 00 C4 01 81 00 09 08 39 30 38 33 34 35 31 37 E0 D6 7E

Thanks
Mohan

Mohanraj

6 years 10 months ago

Hi Any update please?

Hi Any update please?

Profile picture for user Kurumi

Kurumi

6 years 10 months ago

Hi,

Hi,

This is now tested with several different PCs without problems.
Have you set data to NULL?

char* data = NULL;
gxData myobject;
cosem_init(BASE(myobject), DLMS_OBJECT_TYPE_DATA, "0.0.96.1.0.255");
com_read(connection, BASE(myobject), 2);
obj_toString(BASE(myobject), &data);
printf("%s\r\n", data);

If you have still problems let me know the compiler and environment that you are using.
Make sure that you have the latest version.

BR,
Mikko

Mohanraj

6 years 10 months ago

In reply to Hi, by Kurumi

data is not set to null.Thank

data is not set to null.Thank you.

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Landis E650 meter reading over DLMS
  • class_id = 40, version = 2, pushsetup Unparsed data frame
  • GXObisValueItem entries without MaskSize appear to be interpreted as bit flags
  • CheckedListBox incorrectly selects GXObisValueItem Value=0 for non-zero values
  • UIValueType=TextBox is rendered as CheckedListBox when Values are defined
More

Who's new

  • Sayang
  • q80435762@gmail.com
  • ONCAK
  • Berhasil
  • ratirvivege1979
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin