  2. Forums
  3. Trying With Holley Meter, Help Please!

Trying with holley meter, help please!

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By hurani , 17 November, 2019
Forums
Gurux DLMS for Android

Hi all,
I am researching for a project to read data from holley meter using bluetooth probe, I succefully connected to it using android (BluetoothSSP Library), then I tried to send String :
--> /?!\r\n
the meter replied with
<-- /HLY5\(Model Number)
then I tried to send SNRM request but there is no reply, I sent it as string and I tried as bytes but no reply, may you assist me?
--> 7E A0 07 03 23 93 BF 32 7E
and this:
--> 7E A0 07 03 21 93 0F 01 7E
I tried everything but no replied!
How to send it maybe in ASCII? PDU?
Thanks in advance

hurani

6 years 6 months ago

This from official program of

This from official program of Holley:
S: 55 AF 3F 21 8D 0A
R:

S: 7E A0 07 03 23 53 B3 F4 7E
R:

S: 55 AF 3F 21 8D 0A
R: AF 48 CC 59 35 5C B2 44 44 53 44 B2 B8 35 8D 0A

S: 06 B2 35 B2 8D 0A
R: 06 B2 35 B2 8D 0A

S: 7E A0 07 03 23 93 BF 32 7E
R: 7E A0 1E 23 03 73 7B CF 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

S: 7E A0 48 03 23 10 62 20 E6 E6 00 60 3A 80 02 02 84 A1 09 06 07 60 85 74 05 08 01 01 8A 02 07 80 8B 07 60 85 74 05 08 02 01 AC 0A 80 08 30 30 31 31 32 32 33 33 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 FF FF FF 28 00 B7 C6 7E
S: 7E A0 07 03 23 53 B3 F4 7E
R: 7E A0 1E 23 03 73 7B CF 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

S: 55 AF 3F 21 8D 0A
R: AF 48 CC 59 35 5C B2 44 44 53 44 B2 B8 35 8D 0A

S: 06 B2 35 B2 8D 0A
R: 06 B2 35 B2 8D 0A

S: 7E A0 07 03 23 93 BF 32 7E
R: 7E A0 1E 23 03 73 7B CF 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

S: 7E A0 48 03 23 10 62 20 E6 E6 00 60 3A 80 02 02 84 A1 09 06 07 60 85 74 05 08 01 01 8A 02 07 80 8B 07 60 85 74 05 08 02 01 AC 0A 80 08 30 30 31 31 32 32 33 33 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 FF FF FF 28 00 B7 C6 7E
S: 7E A0 07 03 23 53 B3 F4 7E
R: 7E A0 1E 23 03 73 7B CF 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

S: 55 AF 3F 21 8D 0A
R: AF 48 CC 59 35 5C B2 44 44 53 44 B2 B8 35 8D 0A

S: 06 B2 35 B2 8D 0A
R: 06 B2 35 B2 8D 0A

S: 7E A0 07 03 23 93 BF 32 7E
R: 7E A0 1E 23 03 73 7B CF 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

S: 7E A0 48 03 23 10 62 20 E6 E6 00 60 3A 80 02 02 84 A1 09 06 07 60 85 74 05 08 01 01 8A 02 07 80 8B 07 60 85 74 05 08 02 01 AC 0A 80 08 30 30 30 30 30 30 30 30 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 FF FF FF 28 00 68 F4 7E
R: 7E A0 37 23 03 30 D4 C9 E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 18 1D 00 F0 00 07 C2 40 7E

S: 7E A0 19 03 23 32 DF EB E6 E6 00 C0 01 81 00 01 01 00 01 08 00 FE 02 00 11 64 7E
R: 7E A8 89 23 03 52 3E 1C E6 E7 00 C4 01 81 00 02 1C 06 00 23 95 72 06 00 23 95 72 06 00 00 00 00 06 00 00 00 00 06 00 00 00 00 06 00 00 00 06 06 00 00 00 06 06 00 00 00 00 06 00 00 00 00 06 00 00 00 00 06 00 04 3E D1 06 00 08 0D 3A 06 00 23 95 78 06 00 23 95 78 06 00 00 00 00 06 00 00 00 00 06 00 00 00 00 06 00 23 95 6C 06 00 23 95 6C 06 00 00 00 00 06 00 00 00 00 06 00 00 00 00 06 00 00 0D A8 06 00 23 45 C5 1C 7E

Profile picture for user Kurumi

Kurumi

6 years 6 months ago

Hi,

Hi,

Change client address to 0x11, authentication level to Low and password to 00112233.

BR,
Mikko

hurani

6 years 6 months ago

In reply to Hi, by Kurumi

So What is the SNRM will be?

So What is the SNRM will be?
7E A0 07 03 23 93 BF 32 7E
This is 11 in hex and 16 in decimal

Profile picture for user Kurumi

Kurumi

6 years 6 months ago

Hi,

Hi,

I believe that this is a typo, but 0x11 =17, not 16.

Now SNRM is the same as in your log from Holley.

BR,
Mikko

hurani

6 years 6 months ago

In reply to Hi, by Kurumi

Yes, sorry ..

Yes, sorry ..
I tried it, but no luck

Profile picture for user Kurumi

Kurumi

6 years 6 months ago

Hi,

Hi,

And you are sending this as a byte array, not a hex string?

BR,
Mikko

hurani

6 years 6 months ago

In reply to Hi, by Kurumi

As byte array like this:

As byte array like this:
byteArray(0x7E,0xA0,0x07,0x03,0x23,0x93,0xBF,0x32,0x7E)
bt.send(byteArray)
Is it correct?

Profile picture for user Kurumi

Kurumi

6 years 6 months ago

Hi,

Hi,

Yes, this is correct. Are you sending "/?!\r" before that? I'm not sure if meter requires that you need to send it first.

BR,
Mikko
BR,
Mikko

hurani

6 years 6 months ago

In reply to Hi, by Kurumi

Yes, I send it before it, and

Yes, I send it before it, and it replies as I said in first comment the model number of meter

hurani

6 years 6 months ago

In reply to Yes, I send it before it, and by hurani

And what is this command?

And what is this command?
55 AF 3F 21 8D 0A
Its reply the same as /?! ..

Edit: I tried guruxDirector with it and it is connected well

Profile picture for user Kurumi

Kurumi

6 years 6 months ago

Hi,

Hi,

I believe that your sniffer settings are not correct.
55 AF 3F 21 8D 0A is "/?!\r"

BR,
Mikko

hurani

6 years 6 months ago

In reply to Hi, by Kurumi

May you guide me what should

May you guide me what should I do? After /?! ..

Profile picture for user Kurumi

Kurumi

6 years 6 months ago

Hi,

Hi,

You need to send data as bytearray. this is not byte array. It's array of integers.

byteArray(0x7E,0xA0,0x07,0x03,0x23,0x93,0xBF,0x32,0x7E)
bt.send(byteArray)

Try to change this to:
buff = byteArray(0x7E,0xA0,0x07,0x03,0x23,0x93,0xBF,0x32,0x7E)
bt.send(buff)

BR,
Mikko

hurani

6 years 6 months ago

In reply to Hi, by Kurumi

I sent the command as array

I sent the command as array of bytes, I am sure ..
If you want I can share code ..
Do I need to do anything before SNRM command?
Is there any way to use iec protocol on holley?

Profile picture for user Kurumi

Kurumi

6 years 6 months ago

Hi,

Hi,

Did you send "06 B2 35 B2 8D 0A" after you have send "/?!\r"?
You also need to change baud-rate.

BR,
Mikko

Profile picture for user Kurumi

Kurumi

6 years 6 months ago

Hi,

Hi,

Can you share what optical probe (head) you are using?

BR,
Mikko

hurani

6 years 6 months ago

In reply to Hi, by Kurumi

Yes, I tried that, same

Yes, I tried that, same

hurani

6 years 6 months ago

In reply to Hi, by Kurumi

Redz kmk119 .. auto mode 4 or

Redz kmk119 .. auto mode 4 or 5
https://shop.marcomweb.it/images/stories/virtuemart/product/redz-kmk119…

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin