Hello,

We are runnning the following command to do an Active Current readout.

We have taken care of the necessary low level security clearance and all commands prior to this command like all three phase voltages, all three phase currents and the power factors are responding just fine.

Tx data 7E A0 19 03 41 DC 4A B3 E6 E6 00 C0 01 81 00 03 01 00 A1 07 00 FF 02 00 09 4F 7E
Read Data: 7ea0114103fc88b1e6e700c401810104baf07e

Can you please advice on what we are missing?

The output doesn't seem to be responding with the right data packet for Active current. We are able to get Line Current just fine.

Thanks

Ambimat.

Profile picture for user Kurumi

Kurumi

6 years 8 months ago

Hi,

Hi,
Meter returns an error. Register object 1.0.161.7.0.255 don't exists. Read the association view with GXDLMSDirector and check what objects exist.

BR,
Mikko

ambimat

6 years 8 months ago

Hi Mikko,

Hi Mikko,

This is the command that we have executed to receive the Association list

Tx data 7e a0 19 03 41 76 1a b9 e6 e6 00 c0 01 81 00 07 01 00 63 80 00 ff 03 00 98 dc 7e

Rx Data: 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"0100a10700ff"0f0212000002041200030906"0100a30700ff"0f0212000002041200030906"0100a50700ff"0f0212000002041200030906"0100a20700ff"0f0212000002041200030906"0100a40700ff"0f0212000002041200030906"0100a60700ff"0f0212008ad37e

We have added extra quotation sign to help you identify the OBIS codes for Active and Reactive Current. The DLMSDirector is not able to read the same but the Association List command we are sending is able to do. Hence we believe the data does exist but we don't know how to interpret this response to capture the data as well as the class ID where this data is provided.

Can you help

Ambimat.

Profile picture for user Kurumi

Kurumi

6 years 8 months ago

Hi,

Hi,
This is the first frame. There is more data and you need to read it all before it can be parsed.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin