By emma2020 , 26 September, 2019
Forums
Gurux.DLMS

I have a meter with the following iec-62056-21 communication.

>> b'/?!\r\n'
<< b'/EAA5JAM300-310111\r\n'
>> b'\x06001\r\n'
<< b'\x01P0\x02(35657)\x03R'
>> b'\x01P1\x02(0000)\x03a'
<< b'\x01B0\x03q'

I send 0000 as password to the meter but meter doesn't accept and exit.
35657 digits change every time I try to login.
Does anyone know what type of algorithm this meter use?

thank you

Profile picture for user Kurumi

Kurumi

6 years 8 months ago

Hi,

Hi,

35657 is a seed. You can try with Elter password. If it doesn't work you must ask it from the manufacturer. The formula is not defined in the IEC specification.

More information from Elster password:

https://www.gurux.fi/node/5415

BR,
Mikko

emma2020

6 years 8 months ago

Thank you Mikko

Thank you Mikko

Manufacturer is not available.
Is there any way to find out what algorithm used?

Regards

Profile picture for user Kurumi

Kurumi

6 years 8 months ago

Hi,

Hi,

If Elster algorithm does not work, it can be anything.
Standard doesn't define the algorithm.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin