Hi

We have a Siemens IM100 DLMS COSEM meter from which we tried to fetch the objects present there. Fetched objects gave four different disconnect control objects. We tried to do connect/ disconnect etc operations with several of these objects and it is working for all of these objects. Why are there four different objects? Which one of these should we be using?

Thanks
Yatin
-Siemens

Profile picture for user Kurumi

Kurumi

8 years 6 months ago

Several Disconnect Control objects.

Hi,

Amount of disconnect control objects depends from the meter. In some meters, there are no releys at all and in some there are several. In your meter, there are four relays that you can operate.

So there is a different disconnect control for each relay.

BR,

Mikko

Siemens-US

8 years 6 months ago

Several Disconnect Control objects.

Thanks for your reply.

Is there a way to know for which of these objects when a disconnection call is made, the load connected to the meter gets disconnected and on a reconnect method call, the load gets connected?

Thanks
Yatin
-Siemens

Profile picture for user Kurumi

Kurumi

8 years 6 months ago

Several Disconnect Control objects.

Hi,

If you have access to the "Blue book", it's described on "4.5.8 Disconnect control (class_id = 70, version = 0)". Output state shows the actual physical state of the device that is connected the supply.

BR,

Mikko

Siemens-US

8 years 6 months ago

Yes, but I am getting

Yes, but I am getting disconnected "false" output on performing disconnect for only the object on which that operation was performed.
Following is a procedure I tried:-
1. Fetched output state for 0.0.96.3.10.255 object - Value comes out to be true.
2. Fetched output state for 0.2.96.3.10.255 object - Value comes out to be true.
3. Then made a disconnect call for 0.2.96.3.10.255 object.
4. Fetched output state for 0.0.96.3.10.255 object - Value still remains true
5. Fetched output state for 0.2.96.3.10.255 object - Value for this object comes out to be false.

So, even on firing disconnect control call on one of the object, the output state comes out to be different for different objects.

Thanks
Yatin
-Siemens

Profile picture for user Kurumi

Kurumi

8 years 6 months ago

Several Disconnect Control objects

Hi,

What are values of control state and control mode?

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin