Don't comment the topic if you have a new question.
You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.
By Paul Adebo, 7 August, 2012
Hi,
I actually am trying to communicate with the Actatris SL7000 meter. The parameters selected are
Client ID : 10 (hex)
Server ID : 1 (hex)
Wait time : 5
Authentication : None
Media : Serial
Manufacturer ID: ACE
Start Protocol : IEC.
I also checked the "Use Logical Name Refrencing".
When I try to connect, I get a response "Failed to recieve reply from device in given time". I decided to monitor the serial line. I discovered that the Flag protocol actually is implemented but when the Gurux editor sends the SNRM Frame,the Meter does not reply, and I get that warning. Why is that so? And how can I fix it?
Communicating with Actatris SL7000.
Hi Paul,
I answered to your question in this thread:
http://www.gurux.fi/node/597
BR,
Mikko