Don't comment the topic if you have a new question.
You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.
By Dlmstudent, 9 April, 2012
Hello I'm trying to connect Actaris SL700 meter using serial port and optical port but i can´t connect the meter. The view log show this
13:17:59 Initializing serial connection.
13:18:01 Send SNRM request.
7E A0 0A 00 00 00 03 21 93 AB 64 7E
13:18:20 Failed to receive reply from the device in given time.
13:25:14 Initializing serial connection.
13:25:14 Send SNRM request.
7E A0 0A 00 00 00 03 21 93 AB 64 7E
13:25:32 Failed to receive reply from the device in given time.
13:25:49 Initializing serial connection.
13:25:49 Send SNRM request.
7E A0 0A 00 00 00 03 21 93 AB 64 7E
13:26:07 Failed to receive reply from the device in given time.
I check and the physical connection is well, the optical probe is good, i don't know what is the problem.
Please helph me and sorry for my english, I am Latin American :)
Hello, in the first post,i had in the device properties how start protocol DLMS, know i configure how start protocol IEC and i get the following view log:
and dialog box say: "Manufacturer type does not match. Manufacturer is SLB and it should be ACE" please explain to me what this means? many thanks for your help
Connect Actaris SL700
Hello, in the first post,i had in the device properties how start protocol DLMS, know i configure how start protocol IEC and i get the following view log:
14:35:36 Initializing serial connection.
14:35:36 HDLC sending:/?!
14:35:37 HDLC received: /SLB5\2SLB_AMBER_000001
and dialog box say: "Manufacturer type does not match. Manufacturer is SLB and it should be ACE" please explain to me what this means? many thanks for your help
Connect Actaris SL700
Hi,
You should select Atraris to the manufacturer.
See default settings from here:
http://www.gurux.fi/GXDLMSDirectorExample
BR,
Mikko