DLMS Response Returns BCD value

By DLMSHexingDev , 22 December, 2025
Forums
Gurux.DLMS

Hi everyone. I am reading OBIS 1.0.1.6.0.255 from a Hexing HXE310KP meter via GSM using Gurux.DLMS. I receive the following response packet:

00-01-00-01-00-10-00-09-C4-01-41-00-0D-03-17-93-80

I can see that the last three bytes correspond to the value I obtain when reading the meter using HexView software. However, when reading the same OBIS via Gurux, the value returned is only the BCD value 3.

What could be the cause of this discrepancy?

Thanks in advance for your time and assistance.

Profile picture for user Kurumi

Kurumi

10 months 3 weeks ago

Hi, DLMS standards define…

Hi,

DLMS standards define that the BCD value is an Integer8 and its size is one byte.
This means that this is implemented incorrectly to meter. You need to ask if there is a firmware update available that fixes this.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101
  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202

New forum topics

  • Landis E650 meter reading over DLMS
  • class_id = 40, version = 2, pushsetup Unparsed data frame
  • GXObisValueItem entries without MaskSize appear to be interpreted as bit flags
  • CheckedListBox incorrectly selects GXObisValueItem Value=0 for non-zero values
  • UIValueType=TextBox is rendered as CheckedListBox when Values are defined