Hii,
I integrated dlms-client to one of micro controller using the reference of "GuruxDLMSDataCollector" and i am able to read Name plate and instantaneous profiles. But i tried to read billing and daily Load profiles but not able to reading . what i observed is the TX packet is not generating correct packet. But other two Profile generic data types Name plate and Instantaneous i got the correct data from meter.
So could you please help to overcome to read this daily load and billing profile.
Thanks & Regards
srikanth Jogi
Hi srikanth Jogi, Reading…
Hi srikanth Jogi,
Reading the name plate is done in the same way as billing and daily load profiles. Check your code and that you are using the correct logican name (OBIS code) when reading billing and daily load profiles.
BR,
Mikko