By Danlew2018, 8 July, 2025 Forums General discussion Hi, Can someone explain in simple terms how reading load profile data works on an L+G E560 meter? Hi, I'm afraid that it's not… Hi, I'm afraid that it's not so easy. You need to read capture objects, and then you can read the buffer using read by range/entry. Check this link. https://www.gurux.fi/Gurux.DLMS.Objects.GXDLMSProfileGeneric I propose that you download GXDLMSDirector and select L+G as a manufacturer. Then establish the connection to the meter and read it. I believe it will help you to understand DLMS meters. BR, Mikko
Hi, I'm afraid that it's not… Hi, I'm afraid that it's not so easy. You need to read capture objects, and then you can read the buffer using read by range/entry. Check this link. https://www.gurux.fi/Gurux.DLMS.Objects.GXDLMSProfileGeneric I propose that you download GXDLMSDirector and select L+G as a manufacturer. Then establish the connection to the meter and read it. I believe it will help you to understand DLMS meters. BR, Mikko
Hi, I'm afraid that it's not…
Hi,
I'm afraid that it's not so easy.
You need to read capture objects, and then you can read the buffer using read by range/entry. Check this link.
https://www.gurux.fi/Gurux.DLMS.Objects.GXDLMSProfileGeneric
I propose that you download GXDLMSDirector and select L+G as a manufacturer.
Then establish the connection to the meter and read it. I believe it will help you to understand DLMS meters.
BR,
Mikko