Conexión Landis ZMG310 Protocolo IEC

By Rosa , 12 May, 2025
Forums
Gurux DLMS for Android

Buenos días,

Estoy intentando acceder a un contador Landis ZMG310 que usa protocolo IEC, sé las claves que debo usar para lectura y escritura, pero no sé que parámetros debo cambiar en la pantalla de Meter Settings para que consiga conectarme a el. ¿Sabe qué parámetros deben cambiarse para poder conectar a un contador de esas características usando su app?

Profile picture for user Kurumi

Kurumi

1 year 4 months ago

Hi, Companies implement IEC…

Hi,

Companies implement IEC 62056-21 differently. Check this link. I believe it will help you.
https://www.gurux.fi/Elster1700

BR,
Mikko

Rosa

1 year 4 months ago

La cuestión es que nuestros…

La cuestión es que nuestros medidores ya tienen una contraseña para lectura y escritura establecida, pero no entiendo qué parámetros son los que debo indicar para la dirección de cliente, dirección lógica, dirección física, tipo de dirección y autentificación.

Profile picture for user Kurumi

Kurumi

1 year 4 months ago

Hi, I'm afraid that only…

Hi,

I'm afraid that only Landis+Gyr can help you with this. There are differences between IEC 62056-21 implementations between the manufacturers.

You can try to get the readout from the meter. Send /?!\r\n as described on the lish I shared before.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin