By arobles , 21 November, 2022
Forums
Gurux.DLMS

Hi,

It is possible to create a template to simulate a meter without having an actual smart meter to read the data?

I have used the crystal.xml file to understand its operation, but I only get what is related to the attached image.

Image
Profile picture for user Kurumi

Kurumi

3 years 8 months ago

Hi,

Hi,

Please, don't add images. They are hard to read. You have created a simulated meter to TCP/IP port 1000.
You can connect for the meter for example with GXDLMSDirector. Just set the TCP/IP host name and address and establish the connection for the meter.

BR,
Mikko

arobles

3 years 8 months ago

Thanks, I have another

Thanks, I have another question, is there a way to create simulated data that is stored in the meter, data related to measurement?

Profile picture for user Kurumi

Kurumi

3 years 8 months ago

Hi,

Hi,

Values that are read from the meter are base values. You can change those values for the XML file or add your own functionality for the simulator for PreRead -method.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More

Who's new

  • IUJbutxeSTSNcNRN
  • Peraturaidetetug
  • NnmIomcqcTDVWiDuCD
  • iRnseovnShdVWR…
  • HgGuaAJJjTLjzz…
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin