Hello,
I am new in DLMS, I am worked on sumeru verde energy meter(ERP300p).
My meter password is 2222222222222222 and It used a high-level password.
7E A0 4C 03 61 10 58 27 E6 E6 00 60 3E A1 09 06 07 60 85 74 05 08 01 01 8A 02 07 80 8B 07 60 85 74 05 08 02 02 AC 12 80 10 33 63 4F 46 1F 73 4E 77 2F 58 14 1D 28 40 0A 19 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 00 1E 1D FF FF F0 2D 7E
<HDLC len="4B" >
<TargetAddress Value="1" />
<SourceAddress Value="30" />
<!-- AARQ frame. -->
<FrameType Value="10" />
<PDU>
<AssociationRequest>
<ApplicationContextName Value="LN" />
<SenderACSERequirements Value="1" />
<MechanismName Value="High" />
<CallingAuthentication Value="33634F461F734E772F58141D28400A19" />
<InitiateRequest>
<ProposedDlmsVersionNumber Value="06" />
<ProposedConformance>
<ConformanceBit Name="BlockTransferWithGetOrRead" />
<ConformanceBit Name="BlockTransferWithSetOrWrite" />
<ConformanceBit Name="BlockTransferWithAction" />
<ConformanceBit Name="MultipleReferences" />
<ConformanceBit Name="Get" />
<ConformanceBit Name="Set" />
<ConformanceBit Name="SelectiveAccess" />
<ConformanceBit Name="Action" />
</ProposedConformance>
<ProposedMaxPduSize Value="FFFF" />
</InitiateRequest>
</AssociationRequest>
</PDU>
</HDLC>

Please, let me know how the CallingAuthentication function works.

Regards
Manish

Profile picture for user Kurumi

Kurumi

5 years 10 months ago

Hi,

Hi,

Answering this question would that a long time. This is described in the DLMS standard. I believe the best way is if you read it from there.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • Anaglyfos Trading CC
  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin