CallingAuthentication function.

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

Profile picture for user gzpmanish
By gzpmanish , 3 November, 2020
Forums
Gurux.DLMS

Hello,
I am new in DLMS, I am worked on sumeru verde energy meter(ERP300p).
My meter password is 2222222222222222 and It used a high-level password.
7E A0 4C 03 61 10 58 27 E6 E6 00 60 3E A1 09 06 07 60 85 74 05 08 01 01 8A 02 07 80 8B 07 60 85 74 05 08 02 02 AC 12 80 10 33 63 4F 46 1F 73 4E 77 2F 58 14 1D 28 40 0A 19 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 00 1E 1D FF FF F0 2D 7E
<HDLC len="4B" >
<TargetAddress Value="1" />
<SourceAddress Value="30" />
<!-- AARQ frame. -->
<FrameType Value="10" />
<PDU>
<AssociationRequest>
<ApplicationContextName Value="LN" />
<SenderACSERequirements Value="1" />
<MechanismName Value="High" />
<CallingAuthentication Value="33634F461F734E772F58141D28400A19" />
<InitiateRequest>
<ProposedDlmsVersionNumber Value="06" />
<ProposedConformance>
<ConformanceBit Name="BlockTransferWithGetOrRead" />
<ConformanceBit Name="BlockTransferWithSetOrWrite" />
<ConformanceBit Name="BlockTransferWithAction" />
<ConformanceBit Name="MultipleReferences" />
<ConformanceBit Name="Get" />
<ConformanceBit Name="Set" />
<ConformanceBit Name="SelectiveAccess" />
<ConformanceBit Name="Action" />
</ProposedConformance>
<ProposedMaxPduSize Value="FFFF" />
</InitiateRequest>
</AssociationRequest>
</PDU>
</HDLC>

Please, let me know how the CallingAuthentication function works.

Regards
Manish

Profile picture for user Kurumi

Kurumi

5 years 7 months ago

Hi,

Hi,

Answering this question would that a long time. This is described in the DLMS standard. I believe the best way is if you read it from there.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin