Push Notification Parsing

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Bhaumik , 12 February, 2020
Forums
Gurux.Net

Hi Mikko

I am getting the push notification data from the meter and also able to see parsed data in to GXDLMSDirector in Notification window.

In that how we can check that which objects data are received ?

In GXDLMSDirector, we can see parsed value in XML format. Is there anything from which we can understand that which objects data are there in push notification?

Following is the parsed xml
<WRAPPER len="88" >
<TargetAddress Value="1" />
<SourceAddress Value="40" />
<PDU>
<DataNotification>
<LongInvokeIdAndPriority Value="D00006A5" />
<DateTime Value="07E4020C03120802FFFEB600" />
<NotificationBody>
<DataValue>
<Structure Qty="0D" >
<String Value="ABCD0000000" />
<OctetString Value="0000190900FF" />
<OctetString Value="07E4020C03120802FFFEB600" />
<Float32 Value="4362DC29" />
<Float32 Value="3D8F5C29" />
<Float32 Value="443A0000" />
<Float32 Value="41200000" />
<Float32 Value="41200000" />
<UInt16 Value="0016" />
<UInt32 Value="00000003" />
<Float32 Value="00000000" />
<Boolean Value="true" />
<UInt32 Value="00004380" />
</Structure>
</DataValue>
</NotificationBody>
</DataNotification>
<GeneralGloCiphering>
<SystemTitle Value="41424344450303030" />
<CipheredService Value="300000452101F3864F51BCA61FEC47BD31A2DBE7C69F11B6238A09BFA7AA027C0AC5908CABE502D7DDB07B1B4FE8777FE3DE09FF48C2217A7409F5D47F90FC1ACF0847228C31B589533650D8637AB109753B0716C1A453E7F38E8AD3E3AD98314CB1F06322C4D657D18D4E3D70918E244F45A4B9E4" />
</GeneralGloCiphering>
</PDU>
</WRAPPER>

Profile picture for user Kurumi

Kurumi

6 years 4 months ago

Hi,

Hi,

Content of Push notifications might be anything. You need to know what meter is sending. On option is to save the Push Object list to the push list. Some meters are sending the logical name of the push object as the first parameter. There is no simple solution for this.

BR,
Mikko

Bhaumik

6 years 3 months ago

Hi Mikko,

Hi Mikko,

Is there any specific push notification data format (Smart meter to HES ) defined in Indian Standard 16444 ?

Profile picture for user Kurumi

Kurumi

6 years 3 months ago

Hi,

Hi,

The version from IS 16444 that I have don't define the content of the push messages.
They might be defined on the other IS standards.

BR,
Mikko

Bhaumik

6 years 3 months ago

Hi Mikko,

Hi Mikko,

Can you please check in IS15959 and IS15959-2 as well ?

Thanks

Profile picture for user Kurumi

Kurumi

6 years 3 months ago

Hi,

Hi,

IS15959-2 defines some push messages, for example 0.0.25.9.1.255.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin