Hi

i am using gurux java. i am unable to understand how you are doing parsing of different meters data using same way. i mean how you are detecting that meter will return data in this particular format.
because i am trying to read profile generic by using readRowsByEntry() method directly without reading association view. here i am using two meters Landis+gyr and secure and received data from these meters is (from Landis+gyr)
[[ [7, -31, 12, 1, 5, 0, 0, 0, -1, -128, 0, 0], 0, 15593, 506, 1893, 838, 5079, 774, 1374, 550, 4574, 1
204, 1408, 15861, 518, 1931, 852, 5146, 785, 1396, 560, 4669, 0, 11/21/17 12:30:
PM, 0, 11/20/17 6:00:PM, 0, 11/20/17 9:00:PM, 0, 11/20/17 10:00:PM, 0, 11/21/17
5:00:AM, 0, 11/21/17 6:00:AM, 0, 11/21/17 8:00:AM, 0, 11/21/17 9:00:AM, 0, 11/21
/17 12:30:PM, 0, 11/20/17 3:00:PM, 0, 11/20/17 6:00:PM, 0, 11/14/17 9:00:PM, 0,
11/20/17 10:00:PM, 0, 11/18/17 2:00:AM, 0, 11/6/17 6:00:AM, 0, 11/21/17 8:00:AM,
0, 11/9/17 8:30:AM, 0, 11/20/17 3:00:PM, 18116, 25080]]

(from Secure)

[[0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 619, 513, 619,
513, 160, 116, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 18 12:0
0:AM, 18 12:00:AM, 18 12:00:AM, 18 12:00:AM, 18 12:00:AM, 18 12:00:AM, 18 12:00:
AM, 18 12:00:AM, 18 12:00:AM, 18 12:00:AM, 18 12:00:AM, 18 12:00:AM, 18 12:00:AM
, 18 12:00:AM, 18 12:00:AM, 18 12:00:AM, 18 12:00:AM, 18 12:00:AM,[7, -31, 12, 1, 5, 0, 0, 0, -1, -128, 0, 0]]]

here you will find that i am getting hex values([7, -31, 12, 1, 5, 0, 0, 0, -1, -128, 0, 0]) starting(in Landis+gyr) and ending(in secure). how i can get directly date and how you are differentiating meters.
and i don't want anything to input from user. i want user just connect serial port and receive data. how can i do this.

Thanks

Profile picture for user Kurumi

Kurumi

8 years 4 months ago

parsing of different meter data

Hi,

DLMS is very complicated protocol. You don't just send few bytes and get a reply.
I believe that best way is if you use our DLMS components to communicate with your meter.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin