Hi,

Sorry for my English not very good ...

After testing OpenMUC jDLMS, we are testing a meter simulator prototype, we try to use the library gurux.dlms.java to implement the DLMS server part . We have seen in the examples that communication between client and server is based on DLMS TCP / HDLC protocols, but in our case the communication is based on MQTT Messaging.

Question :
What is the good practice to add a custom protocol without having to fundamentally change the existing code of Gurux ?
(communication is made via an MQTT broker between client and DLMS server instances)

Thank you in advance.

Mansour

Profile picture for user Kurumi

Kurumi

10 years 2 months ago

Communication between DLMS client/server other than TCP/HDLC

Hi,

I believe that you have PLC modem or PLC serial port converter. What meter and converter you are using?
BR,
Mikko

mansour

10 years 2 months ago

In reply to Communication between DLMS client/server other than TCP/HDLC by Kurumi

Communication between DLMS client/server other than TCP/HDLC

Hi,

Yes we have a PLC Modem ON Semiconductor (NCN49597) and for the meters we try to simulate different manufacturers.

Mansour

frato

8 years 4 months ago

Communication between DLMS client/server other than TCP/HDLC

Hello, I am testing the compatibility of the gurux client with the openmuc server and I can not make it go. I have also tried actaris ace6000 with the openmuc client and it has not worked for me, I think it's a configuration problem, have not you had any problems using openmuc?
Thank you

Profile picture for user Kurumi

Kurumi

8 years 4 months ago

Communication between DLMS client/server other than TCP/HDLC

Hi frato,

Please, make own topic if you have a new question. Check client and server addresses. They are usually causing problems if you are not receiving an answer from the server.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
  • dw772
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin