By dlmsDeveloper , 29 December, 2022
Forums
Gurux.Net

Dear Gurux Manager
Hi

I use gurux.net and gurux.dlms C# for Read my devices
but i cant handle multiple meter read with an open port

i use this for open port :

GXNet server = new GXNet(NetworkType.Tcp, 777);
server.HostName = "x.x.x.x";
server.Port = 5060;
server.Open();
server.OnClientConnected += OnClientConnected;

and OnClientConnected method is:

GXNet server = (GXNet)sender;
try
{
using (GXNet cl = server.Attach(e.Info))
{
ReadMeter(cl, e.Info))
}
}
catch (Exception ex)
{
}

in this case when the second meter is connected, it waits until the first meter is disconnected.
How can I read all these together?

thanks.

Profile picture for user Kurumi

Kurumi

3 years 8 months ago

Hi,

Hi,

You need to create a thread in OnClientConnected that then reads the meter. In that way, it's not blocking the connection.

Something like this:
GXNet media = server.Attach(e);
Thread thread = new Thread(new ParameterizedThreadStart(ReadMeter));
thread.Start(media);

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
  • dw772
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin