Hello,
Is there a way to find OBIS code from a ReadRequest trace?
For example this HDLC frame: 7E A0 11 03 41 FE 82 54 E6 E6 00 05 01 02 9A F0 8A 80 7E
means a readRequest for OBIS code 1.1.32.7.0.255
GURUX DLMS translator returns this:
<HDLC len="10" >
<TargetAddress Value="1" />
<SourceAddress Value="20" />
<FrameType Value="FE" />
<PDU>
<ReadRequest Qty="01" >
<VariableName Value="9AF0" />
</ReadRequest>
</PDU>
</HDLC>

How to get the OBIS code from the 9A F0 value?

Thanks,

Arian

Profile picture for user Kurumi

Kurumi

3 years 12 months ago

Hi Arian,

Hi Arian,

ReadRequest is using short name referencing and there is only Int16 value that tells what to read. You need to read the association view and you can find the logical name that is mapped for the short name from there.

In short: It's not possible to get the logical name from the short name.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
  • dw772
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin