Hello

I'm trying to read EDMI ATLAS MK7MI using RS-232 port. Information from brochure this meter using DLMS IEC62056 protocol in all ports including RS-232. But other EDMI ATLAS line up using 'EDMI Command Line' ex. MK10E which i can understand this protocol.

My Question is, what protocol is used by MK7MI in RS-232 port. And what steps to connect meter using DLMS protocol with Gurux DLMS Director via RS-232 port.

Thanks.

Profile picture for user Kurumi

Kurumi

4 years 1 month ago

Hi,

Hi,

I know that the all meter versions don't support DLMS. If I remember right the optical port is supporting only IEC 62056-21. You need to ask the meter vendor if your meter is supporting DLMS.

You can read more about the differences between IEC 62056-21 and DLMS here:
https://www.gurux.fi/DLMSCOSEMFAQ

BR,
Mikko

Profile picture for user hasan nasha

hasan nasha

4 years 1 month ago

Thanks for your reply.

Thanks for your reply.

I ask vendor and he clarify that meter only support IEC 62056-21.
And i try to connect meter via rs232 port with IEC 62056-21 frame command. I send "/?!\r\n" and i receive the same command that i send past. I managed to try other baudrate, parity, and stop bits, but same same as before. Do i have a wrong step?

Thanks

Profile picture for user hasan nasha

hasan nasha

4 years 1 month ago

In reply to Thanks for your reply. by hasan nasha

i try using rs485 because in

i try using rs485 because in facsheet this meter supports rs232/rs485. I got response from meter, but not same with iec 62056-21 data frame. is it posible EMDI use own iec 62056-21?

Image
Profile picture for user Kurumi

Kurumi

4 years 1 month ago

Hi,

Hi,

There are some variations between IEC 62056-21, but it seems like your meter is sending readout for /?!\r\n. What you need to do is read data until you receive 0xD 0xA.

In readout there are some current values that you can parse.

I hope this will help you. It's for Elster, but the idea is the same.
https://www.gurux.fi/node/5415

BR,
Mikko

Profile picture for user hasan nasha

hasan nasha

4 years 1 month ago

Thanks for your help. I might

Thanks for your help. I might try with method and other port soon.

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
  • dw772
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin