By Varun Sharma , 11 January, 2021
Forums
General discussion

Hello sir
My application was working fine but from 2 3 days i m not able to download meter it always get stuck on same line while downloading using gprs

<- 3:46:21 PM 7E A0 20 03 41 93 28 BC 81 80 14 05 02 01 16 06 02 01 16 07 04 00 00 00 01 08 04 00 00 00 01 94 42 7E
-> 3:46:22 PM 7E A0 20 41 03 73 3E 9D 81 80 14 05 02 01 16 06 02 01 16 07 04 00 00 00 01 08 04 00 00 00 01 94 42 7E
<- 3:46:22 PM 7E A0 42 03 41 10 29 AA E6 E6 00 60 34 A1 09 06 07 60 85 74 05 08 01 01 8A 02 07 80 8B 07 60 85 74 05 08 02 01 AC 08 80 06 31 32 33 34 35 36 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 00 1E 1D FF FF 4C 5C 7E
-> 3:46:23 PM 7E A0 37 41 03 30 21 79 E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 10 14 01 16 00 07 3D F3 7E
<- 3:46:23 PM 7E A0 19 03 41 32 3A BD E6 E6 00 C0 01 C1 00 07 01 00 5E 5B 00 FF 07 00 29 3C 7E
-> 3:46:23 PM 7E A0 15 41 03 52 10 8F E6 E7 00 C4 01 C1 00 06 00 00 00 01 F4 09 7E
<- 3:46:23 PM 7E A0 19 03 41 54 0A BB E6 E6 00 C0 01 C1 00 07 01 00 5E 5B 00 FF 02 00 91 42 7E
-> 3:46:24 PM 7E A0 D2 41 03 74 DC A7 E6 E7 00 C4 02 C1 01 00 00 00 01 00 82 00 BA 01 82 00 01 02 1E 09 0C 07 E5 01 0B FF 0F 2E 01 FF 80 00 00 06 00 00 00 04 06 00 00 00 00 06 00 00 00 00 06 00 00 57 46 06 00 00 00 00 06 00 00 00 00 06 00 00 00 00 06 00 00 00 00 06 00 00 00 00 06 00 00 00 00 06 00 00 C3 34 06 00 00 00 00 06 00 00 00 00 06 00 00 00 00 12 00 0E 06 00 00 15 E2 12 00 06 06 00 00 00 00 12 00 00 09 0C FF FF FF FF FF FF FF FF FF 80 00 00 06 00 00 00 00 06 00 00 00 00 06 00 00 00 00 06 00 00 00 00 06 00 00 00 00 09 0C FF FF FF FF FF FF FF FF FF 80 00 00 06 00 00 00 00 09 0C FF FF FF FF FF FF FF FF FF 80 00 00 06 00 00 00 00 E2 25 7E
<- 3:46:24 PM 7E A0 19 03 41 76 1A B9 E6 E6 00 C0 01 C1 00 07 01 00 5E 5B 00 FF 03 00 49 5B 7E
Data send failed. Trying to resend
<- 3:46:34 PM 7E A0 19 03 41 76 1A B9 E6 E6 00 C0 01 C1 00 07 01 00 5E 5B 00 FF 03 00 49 5B 7E
Data send failed. Trying to resend
-> 3:46:56 PM 7E A1 2A 41 03 96 77 FA E6 E7 00 C4 02 C1 00 00 00 00 01 00 82 01 12 01 82 00 1E 02 04 12 00 08 09 06 00 00 01 00 00 FF 0F 02 12 00 7E A0 07 41 03 97 66 E4 7E
-> 3:46:56 PM 7E A1 2A 41 03 96 77 FA E6 E7 00 C4 02 C1 00 00 00 00 01 00 82 01 12 01 82 00 1E 02 04 12 00 08 09 06 00 00 01 00 00 FF 0F 02 12 00 7E A0 07 41 03 97 66 E4 7E
<- 3:46:56 PM 7E A0 19 03 41 98 6A B7 E6 E6 00 C0 01 C1 00 07 01 00 5E 5B 03 FF 02 00 5C 67 7E
-> 3:46:58 PM 7E A0 07 41 03 97 66 E4 7E
>> 00000005 is Disconnected 11-Jan-21 3:46:58 PM

Profile picture for user Kurumi

Kurumi

5 years 8 months ago

Hi Varun,

Hi Varun,

I seem that your meter is closing the connection after you read 1.0.94.91.0.255. The first read failed and for the second read, the meter returns an invalid frame. Check if your meter is rebooting when you read profile generic buffer.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
  • dw772
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin