Hii,

My meter is in suite 1 and i want to communicate with the meter in suite 1 mode.

I have successfully shared the certificates of each other (Gurux client and meter) using certificate attributes and methods in suite 0.

Now i have changed the settings from "Secured Connections" tab which snap is attached here with this post.

When i click on connect button i found that Gurux send AARQ frame request in which No signing tag and no signature is there in the frame:

Log :

13:12:56 Send SNRM request.
TX: 7E A0 23 00 02 BA 69 C1 93 05 72 81 80 14 05 02 02 00 06 02 02 00 07 04 00 00 00 01 08 04 00 00 00 01 6F EF 7E
13:13:06 Failed to receive reply from the device in given time.
13:13:06 Send Disconnect request.
TX: 7E A0 0A 00 02 BA 69 C1 53 B3 96 7E
13:13:16 Failed to receive reply from the device in given time.

AARQ plain data : 01 00 00 00 06 5F 1F 04 00 00 1E 1D FF FF

Can please suggest where i am doing mistack in settings?

Best Regards,
Aoudumbar Pawar