Hi I am using DLMS director and reading DLMS server meter without using password in RS-485 multi drop connection.
Below is the request and response of instant snap command, but the response is not clear. can any one help me out.
7e // HDLC frame opening flag
a011// frame type and length
410291 //Server and client address
52//Frame type
ef06 //Header check sequence
e6e700// LLC bytes
0e 01 03 02 //DLMS Data
94a8 // Frame check sequence
7e // HDLC frame closing flag
Do you have problems with GXDLMSDirector or are you just
interested from the DLMS frame structure?
DLMS frame
Hi,
Below is structure of received frame.
7e // HDLC frame opening flag
a011// frame type and length
410291 //Server and client address
52//Frame type
ef06 //Header check sequence
e6e700// LLC bytes
0e 01 03 02 //DLMS Data
94a8 // Frame check sequence
7e // HDLC frame closing flag
Do you have problems with GXDLMSDirector or are you just
interested from the DLMS frame structure?
BR,