Change type failed. Not enought data

6 posts / 0 new
Last post
salman1538
Change type failed. Not enought data

Hi All, I try to read date and time from Meter.

1.1.0.9.1.255:2 -> I get the time

1.1.0.9.2.255:2 -> I get the message change type failed. Not enought data

I am using Gurux DLMS Client Example in Python.

Please guide to resolve the error.

Regards,

Kurumi
Kurumi's picture

Hi,

Can you add a trace from the bytes so I can check it?

BR,
Mikko

________________________________________
Mikko Kurunsaari
Gurux Ltd
http://www.gurux.fi

salman1538

Hi, thanks for reply. Below is the trace from log file -t Verbose

[Trace removed]

Salman1538

Kurumi
Kurumi's picture

Hi,

I was able to repeat this. I create an issue from this and a new version is released later today.
https://www.gurux.fi/node/18287
BR,
Mikko

________________________________________
Mikko Kurunsaari
Gurux Ltd
http://www.gurux.fi

salman1538

Hi,

Thanks for quick support. Got the new version 1.0.103 - Will update after test.

Salman1538

salman1538

Hi,

I test and it works fine. Thank you.

Regards,

Salman1538