Before commenting read Forum rules
Don't comment the topic if you have a new question.
You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.
Before commenting read Forum rules
Don't comment the topic if you have a new question.
You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.
Hello,
I am used Sumeru verde energy meter(ERP300P).
I am used Gurux.DLMS.Python to read the value of energy meter.
My energy meter is high level password and its password is 2222222222222222.
I am run the command python main.py -S /dev/ttyUSB0 -a High -P 2222222222222222 -c 48.
Its given a errors...
gurux_dlms version: 1.0.93
gurux_net version: 1.0.17
gurux_serial version: 1.0.15
Authentication: Authentication.HIGH
ClientAddress: 0x30
ServerAddress: 0x1
Standard: Standard.DLMS
Profile Generic 0.0.94.91.10.255Columns:
0.0.96.1.0.255 Ch. 0 Device ID 1, manufacturing number | 0.0.96.1.2.255 Ch. 0 Device ID #3 | 0.0.96.1.1.255 Ch. 0 Device ID #2 | 1.0.0.2.0.255 Ch. 0 Active firmware identifier | 0.0.94.91.9.255 Ch. 0 Identifiers for India | 0.0.94.91.11.255 Ch. 0 Identifiers for India | 0.0.94.91.12.255 Ch. 0 Identifiers for India | 0.0.96.1.4.255 Ch. 0 Device ID #5
Profile Generic 0.0.99.98.1.255Columns:
0.0.1.0.0.255 Ch. 0 Clock object #1 | 0.0.96.11.1.255 | 1.0.94.91.14.255 | 1.0.12.7.0.255 Ch. 0 Voltage: any phase Inst. value | 1.0.13.7.0.255 Ch. 0 Sum Li Power factor Inst. value | 1.0.1.8.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0 (0 is total)
Profile Generic 0.0.99.98.2.255Columns:
0.0.1.0.0.255 Ch. 0 Clock object #1 | 0.0.96.11.2.255
Profile Generic 0.0.99.98.3.255Columns:
0.0.1.0.0.255 Ch. 0 Clock object #1 | 0.0.96.11.3.255
Profile Generic 0.0.99.98.4.255Columns:
0.0.1.0.0.255 Ch. 0 Clock object #1 | 0.0.96.11.4.255 | 1.0.94.91.14.255 | 1.0.12.7.0.255 Ch. 0 Voltage: any phase Inst. value | 1.0.13.7.0.255 Ch. 0 Sum Li Power factor Inst. value | 1.0.1.8.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0 (0 is total)
Profile Generic 0.0.99.98.5.255Columns:
0.0.1.0.0.255 Ch. 0 Clock object #1 | 0.0.96.11.5.255
Profile Generic 0.0.99.98.6.255Columns:
0.0.1.0.0.255 Ch. 0 Clock object #1 | 0.0.96.11.6.255
Profile Generic 1.0.94.91.0.255Columns:
0.0.1.0.0.255 Ch. 0 Clock object #1 | 1.0.12.7.0.255 Ch. 0 Voltage: any phase Inst. value | 1.0.11.7.0.255 Ch. 0 Current: any phase Inst. value | 1.0.91.7.0.255 Ch. 0 Lo Current (neutral) Inst. value | 1.0.13.7.0.255 Ch. 0 Sum Li Power factor Inst. value | 1.0.14.7.0.255 Ch. 0 Supply frequency Inst. value | 1.0.9.7.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Inst. value | 1.0.1.7.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Inst. value | 1.0.1.8.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0 (0 is total) | 1.0.9.8.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Time integral 1 Rate 0 (0 is total) | 1.0.1.6.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Max. 1 Rate 0 (0 is total) | 1.0.1.6.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Max. 1 Rate 0 (0 is total) | 1.0.9.6.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Max. 1 Rate 0 (0 is total) | 1.0.9.6.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Max. 1 Rate 0 (0 is total) | 0.0.94.91.14.255 Ch. 0 Identifiers for India | 0.0.94.91.0.255 Ch. 0 Identifiers for India | 0.0.0.1.0.255 Ch. 0 Billing period counter (1) #255 | 0.0.96.2.0.255 Ch. 0 No. of configuration program changes | 1.0.2.8.0.255 Ch. 0 Sum Li Active power- (QII+QIII) Time integral 1 Rate 0 (0 is total) | 1.0.10.8.0.255 Ch. 0 Sum Li Apparent power- (QII+QIII) Time integral 1 Rate 0 (0 is total) | 0.0.96.3.10.255 Ch. 0 Disconnect control | 0.0.17.0.0.255 Ch. 0 Limiter #1
Profile Generic 1.0.94.91.3.255Columns:
1.0.12.7.0.255 Ch. 0 Voltage: any phase Inst. value | 1.0.11.7.0.255 Ch. 0 Current: any phase Inst. value | 1.0.91.7.0.255 Ch. 0 Lo Current (neutral) Inst. value | 1.0.13.7.0.255 Ch. 0 Sum Li Power factor Inst. value | 1.0.14.7.0.255 Ch. 0 Supply frequency Inst. value | 1.0.9.7.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Inst. value | 1.0.1.7.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Inst. value | 1.0.1.8.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0 (0 is total) | 1.0.9.8.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Time integral 1 Rate 0 (0 is total) | 1.0.1.6.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Max. 1 Rate 0 (0 is total) | 1.0.9.6.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Max. 1 Rate 0 (0 is total) | 0.0.94.91.14.255 Ch. 0 Identifiers for India | 1.0.2.8.0.255 Ch. 0 Sum Li Active power- (QII+QIII) Time integral 1 Rate 0 (0 is total) | 1.0.10.8.0.255 Ch. 0 Sum Li Apparent power- (QII+QIII) Time integral 1 Rate 0 (0 is total) | 0.0.17.0.0.255 Ch. 0 Limiter #1
Profile Generic 1.0.94.91.4.255Columns:
1.0.12.27.0.255 | 1.0.1.29.0.255 | 1.0.9.29.0.255 | 1.0.2.29.0.255 | 1.0.10.29.0.255
Profile Generic 1.0.94.91.5.255Columns:
1.0.2.8.0.255 Ch. 0 Sum Li Active power- (QII+QIII) Time integral 1 Rate 0 (0 is total) | 1.0.10.8.0.255 Ch. 0 Sum Li Apparent power- (QII+QIII) Time integral 1 Rate 0 (0 is total) | 1.0.1.8.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0 (0 is total) | 1.0.9.8.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Time integral 1 Rate 0 (0 is total)
Profile Generic 1.0.94.91.6.255Columns:
1.0.13.0.0.255 | 1.0.1.8.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0 (0 is total) | 1.0.1.8.1.255 | 1.0.1.8.2.255 | 1.0.1.8.3.255 | 1.0.1.8.4.255 | 1.0.9.8.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Time integral 1 Rate 0 (0 is total) | 1.0.9.8.1.255 | 1.0.9.8.2.255 | 1.0.9.8.3.255 | 1.0.9.8.4.255 | 1.0.1.6.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Max. 1 Rate 0 (0 is total) | 1.0.9.6.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Max. 1 Rate 0 (0 is total) | 0.0.94.91.13.255 | 1.0.2.8.0.255 Ch. 0 Sum Li Active power- (QII+QIII) Time integral 1 Rate 0 (0 is total) | 1.0.10.8.0.255 Ch. 0 Sum Li Apparent power- (QII+QIII) Time integral 1 Rate 0 (0 is total)
Profile Generic 1.0.94.91.7.255Columns:
1.0.94.91.14.255 | 1.0.12.7.0.255 Ch. 0 Voltage: any phase Inst. value | 1.0.13.7.0.255 Ch. 0 Sum Li Power factor Inst. value | 1.0.1.8.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0 (0 is total)
Profile Generic 1.0.98.1.0.255Columns:
0.0.0.1.2.255 | 1.0.13.0.0.255 | 1.0.1.8.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0 (0 is total) | 1.0.1.8.1.255 | 1.0.1.8.2.255 | 1.0.1.8.3.255 | 1.0.1.8.4.255 | 1.0.9.8.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Time integral 1 Rate 0 (0 is total) | 1.0.9.8.1.255 | 1.0.9.8.2.255 | 1.0.9.8.3.255 | 1.0.9.8.4.255 | 1.0.1.6.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Max. 1 Rate 0 (0 is total) | 1.0.1.6.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Max. 1 Rate 0 (0 is total) | 1.0.9.6.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Max. 1 Rate 0 (0 is total) | 1.0.9.6.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Max. 1 Rate 0 (0 is total) | 0.0.94.91.13.255 | 1.0.2.8.0.255 Ch. 0 Sum Li Active power- (QII+QIII) Time integral 1 Rate 0 (0 is total) | 1.0.10.8.0.255 Ch. 0 Sum Li Apparent power- (QII+QIII) Time integral 1 Rate 0 (0 is total)
Profile Generic 1.0.99.1.0.255Columns:
0.0.1.0.0.255 Ch. 0 Clock object #1 | 1.0.12.27.0.255 | 1.0.1.29.0.255 | 1.0.9.29.0.255 | 1.0.2.29.0.255 | 1.0.10.29.0.255
Profile Generic 1.0.99.2.0.255Columns:
0.0.1.0.0.255 Ch. 0 Clock object #1 | 1.0.2.8.0.255 Ch. 0 Sum Li Active power- (QII+QIII) Time integral 1 Rate 0 (0 is total) | 1.0.10.8.0.255 Ch. 0 Sum Li Apparent power- (QII+QIII) Time integral 1 Rate 0 (0 is total) | 1.0.1.8.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0 (0 is total) | 1.0.9.8.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Time integral 1 Rate 0 (0 is total)
-------- Reading 1 0.0.0.1.0.255 Ch. 0 Billing period counter (1) #255
Index: 1 Value: 30 2E 30 2E 30 2E 31 2E 30 2E 32 35 35
Index: 2 Value: 3
-------- Reading 1 0.0.0.1.1.255 Ch. 0 No. of available billing periods (1)
Index: 1 Value: 30 2E 30 2E 30 2E 31 2E 31 2E 32 35 35
Index: 2 Value: 3
-------- Reading 8 0.0.1.0.0.255 Ch. 0 Clock object #1
Index: 1 Value: 30 2E 30 2E 31 2E 30 2E 30 2E 32 35 35
Index: 2 Value: 09/06/20 09:29:00:000000
Index: 3 Value: 330
Index: 4 Value: 0
Attribute5 is not readable.
Attribute6 is not readable.
Attribute7 is not readable.
Attribute8 is not readable.
Index: 9 Value: 1
-------- Reading 20 0.0.13.0.0.255 Ch. 0 Activity calendar #1
Index: 1 Value: 30 2E 30 2E 31 33 2E 30 2E 30 2E 32 35 35
Index: 2 Value: 2017
Index: 3 Value: SN01 01/01/20 00:00:00:000000
Index: 4 Value: 57 6B 30 31
Index: 5 Value: 49 00:00:00 0.0.10.0.100.255 10:00:00 0.0.10.0.100.255 12:00:00 0.0.10.0.100.255 15:00:00 0.0.10.0.100.255
Index: 6 Value: 2017
Index: 7 Value: SN01 01/01/20 00:00:00:000000
Index: 8 Value: 57 6B 30 31
Index: 9 Value: 49 00:00:00 0.0.10.0.100.255 10:00:00 0.0.10.0.100.255 12:00:00 0.0.10.0.100.255 15:00:00 0.0.10.0.100.255
Index: 10 Value: /00 00:00:00:000000
-------- Reading 22 0.0.15.0.0.255 Ch. 0 End of billing period
Index: 1 Value: 30 2E 30 2E 31 35 2E 30 2E 30 2E 32 35 35
Index: 2 Value: 30 2E 30 2E 31 30 2E 30 2E 31 2E 32 35 35, 110
Index: 3 Value: 1
Index: 4 Value: 01/01 00:00, 02/01 00:00, 03/01 00:00, 04/01 00:00, 05/01 00:00, 06/01 00:00, 07/01 00:00, 08/01 00:00, 09/01 00:00, 10/01 00:00, 11/01 00:00, 12/01 00:00
-------- Reading 22 0.0.15.0.2.255 Ch. 0 Image activation
Index: 1 Value: 30 2E 30 2E 31 35 2E 30 2E 32 2E 32 35 35
Index: 2 Value: 30 2E 30 2E 31 30 2E 30 2E 31 30 37 2E 32 35 35, 111
Index: 3 Value: 1
Index: 4 Value: 00:00
-------- Reading 22 0.0.15.0.4.255 Ch. 0 Push
Index: 1 Value: 30 2E 30 2E 31 35 2E 30 2E 34 2E 32 35 35
Index: 2 Value: 30 2E 30 2E 31 30 2E 30 2E 31 30 38 2E 32 35 35, 112
Index: 3 Value: 1
Index: 4 Value: 00:00:00:000000
-------- Reading 71 0.0.17.0.0.255 Ch. 0 Limiter #1
Index: 1 Value: 30 2E 30 2E 31 37 2E 30 2E 30 2E 32 35 35
Index: 2 Value: 1.0.1.7.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Inst. value
Index: 3 Value: 15120
Index: 4 Value: 15120
Index: 5 Value: 13000
Index: 6 Value: 60
Index: 7 Value: 60
Index: 8 Value: 116 01/01/01 01:00:00:000000 1800
Index: 9 Value: 120
Index: 10 Value: False
Index: 11 Value: 0.0.10.0.106.255 11, 0.0.10.0.106.255 12
-------- Reading 41 0.0.25.0.0.255 Ch. 0 TCP-UDP setup
Index: 1 Value: 30 2E 30 2E 32 35 2E 30 2E 30 2E 32 35 35
Index: 2 Value: 0
Index: 3 Value: 30 2E 30 2E 30 2E 30 2E 30 2E 30
Index: 4 Value: 0
Index: 5 Value: 0
Index: 6 Value: 0
-------- Reading 48 0.0.25.7.0.255 Ch. 0 IPv6 setup
Index: 1 Value: 30 2E 30 2E 32 35 2E 37 2E 30 2E 32 35 35
Attribute2 is not readable.
Index: 3 Value: AddressConfigMode.AUTO
Error! Index: 4 inet_ntop() argument 2 must be string or read-only buffer, not bytearray
inet_ntop() argument 2 must be string or read-only buffer, not bytearray
Traceback (most recent call last):
File "/home/pi/dlmsMeterCode/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 426, in getReadOut
val = self.read(it, pos)
File "/home/pi/dlmsMeterCode/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 327, in read
return self.client.updateValue(item, attributeIndex, reply.value)
File "/home/pi/.local/lib/python2.7/site-packages/gurux_dlms/GXDLMSClient.py", line 776, in updateValue
target.setValue(self.settings, e)
File "/home/pi/.local/lib/python2.7/site-packages/gurux_dlms/objects/GXDLMSIp6Setup.py", line 247, in setValue
self.unicastIPAddress.append(socket.inet_ntop(socket.AF_INET6, it))
TypeError: inet_ntop() argument 2 must be string or read-only buffer, not bytearray
Error! Index: 5 inet_ntop() argument 2 must be string or read-only buffer, not bytearray
inet_ntop() argument 2 must be string or read-only buffer, not bytearray
Traceback (most recent call last):
File "/home/pi/dlmsMeterCode/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 426, in getReadOut
val = self.read(it, pos)
File "/home/pi/dlmsMeterCode/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 327, in read
return self.client.updateValue(item, attributeIndex, reply.value)
File "/home/pi/.local/lib/python2.7/site-packages/gurux_dlms/GXDLMSClient.py", line 776, in updateValue
target.setValue(self.settings, e)
File "/home/pi/.local/lib/python2.7/site-packages/gurux_dlms/objects/GXDLMSIp6Setup.py", line 254, in setValue
self.multicastIPAddress.append(socket.inet_ntop(socket.AF_INET6, it))
TypeError: inet_ntop() argument 2 must be string or read-only buffer, not bytearray
Error! Index: 6 inet_ntop() argument 2 must be string or read-only buffer, not bytearray
inet_ntop() argument 2 must be string or read-only buffer, not bytearray
Traceback (most recent call last):
File "/home/pi/dlmsMeterCode/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 426, in getReadOut
val = self.read(it, pos)
File "/home/pi/dlmsMeterCode/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 327, in read
return self.client.updateValue(item, attributeIndex, reply.value)
File "/home/pi/.local/lib/python2.7/site-packages/gurux_dlms/GXDLMSClient.py", line 776, in updateValue
target.setValue(self.settings, e)
File "/home/pi/.local/lib/python2.7/site-packages/gurux_dlms/objects/GXDLMSIp6Setup.py", line 261, in setValue
self.gatewayIPAddress.append(socket.inet_ntop(socket.AF_INET6, it))
TypeError: inet_ntop() argument 2 must be string or read-only buffer, not bytearray
Error! Index: 7 inet_ntop() argument 2 must be string or read-only buffer, not bytearray
inet_ntop() argument 2 must be string or read-only buffer, not bytearray
Traceback (most recent call last):
File "/home/pi/dlmsMeterCode/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 426, in getReadOut
val = self.read(it, pos)
File "/home/pi/dlmsMeterCode/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 327, in read
return self.client.updateValue(item, attributeIndex, reply.value)
File "/home/pi/.local/lib/python2.7/site-packages/gurux_dlms/GXDLMSClient.py", line 776, in updateValue
target.setValue(self.settings, e)
File "/home/pi/.local/lib/python2.7/site-packages/gurux_dlms/objects/GXDLMSIp6Setup.py", line 266, in setValue
self.primaryDNSAddress = socket.inet_ntop(socket.AF_INET6, e.value)
TypeError: inet_ntop() argument 2 must be string or read-only buffer, not bytearray
Error! Index: 8 inet_ntop() argument 2 must be string or read-only buffer, not bytearray
inet_ntop() argument 2 must be string or read-only buffer, not bytearray
Traceback (most recent call last):
File "/home/pi/dlmsMeterCode/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 426, in getReadOut
val = self.read(it, pos)
File "/home/pi/dlmsMeterCode/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python/GXDLMSReader.py", line 327, in read
return self.client.updateValue(item, attributeIndex, reply.value)
File "/home/pi/.local/lib/python2.7/site-packages/gurux_dlms/GXDLMSClient.py", line 776, in updateValue
target.setValue(self.settings, e)
File "/home/pi/.local/lib/python2.7/site-packages/gurux_dlms/objects/GXDLMSIp6Setup.py", line 273, in setValue
self.secondaryDNSAddress = socket.inet_ntop(socket.AF_INET6, e.value)
TypeError: inet_ntop() argument 2 must be string or read-only buffer, not bytearray
Attribute9 is not readable.
Attribute10 is not readable.
-------- Reading 15 0.0.40.0.1.255 Ch. 0 Association #1
Index: 1 Value: 30 2E 30 2E 34 30 2E 30 2E 31 2E 32 35 35
Index: 2 Value:
Index: 3 Value: 16, 1
Index: 4 Value: 0 0 0 5 8 1 1
Index: 5 Value: 524288 512 512 6 0
Attribute6 is not readable.
Attribute7 is not readable.
Index: 8 Value: 0
Attribute9 is not readable.
-------- Reading 15 0.0.40.0.2.255 Ch. 0 Association #2
Index: 1 Value: 30 2E 30 2E 34 30 2E 30 2E 32 2E 32 35 35
Attribute2 is not readable.
Attribute3 is not readable.
Attribute4 is not readable.
Attribute5 is not readable.
Attribute6 is not readable.
Attribute7 is not readable.
Attribute8 is not readable.
Attribute9 is not readable.
-------- Reading 15 0.0.40.0.3.255 Ch. 0 Association #3
Index: 1 Value: 30 2E 30 2E 34 30 2E 30 2E 33 2E 32 35 35
Attribute2 is not readable.
Attribute3 is not readable.
Attribute4 is not readable.
Attribute5 is not readable.
Attribute6 is not readable.
Attribute7 is not readable.
Attribute8 is not readable.
Attribute9 is not readable.
-------- Reading 15 0.0.40.0.4.255 Ch. 0 Association #4
Index: 1 Value: 30 2E 30 2E 34 30 2E 30 2E 34 2E 32 35 35
Attribute2 is not readable.
Attribute3 is not readable.
Attribute4 is not readable.
Attribute5 is not readable.
Attribute6 is not readable.
Attribute7 is not readable.
Attribute8 is not readable.
Attribute9 is not readable.
-------- Reading 15 0.0.40.0.5.255 Ch. 0 Association #5
Index: 1 Value: 30 2E 30 2E 34 30 2E 30 2E 35 2E 32 35 35
Attribute2 is not readable.
Attribute3 is not readable.
Attribute4 is not readable.
Attribute5 is not readable.
Attribute6 is not readable.
Attribute7 is not readable.
Attribute8 is not readable.
Attribute9 is not readable.
-------- Reading 1 0.0.42.0.0.255 Ch. 0 COSEM Logical device name
Index: 1 Value: 30 2E 30 2E 34 32 2E 30 2E 30 2E 32 35 35
Index: 2 Value: AGT001-1117-0020
-------- Reading 1 0.0.94.91.0.255 Ch. 0 Identifiers for India
Index: 1 Value: 30 2E 30 2E 39 34 2E 39 31 2E 30 2E 32 35 35
Attribute2 is not readable.
-------- Reading 1 0.0.94.91.9.255 Ch. 0 Identifiers for India
Index: 1 Value: 30 2E 30 2E 39 34 2E 39 31 2E 39 2E 32 35 35
Attribute2 is not readable.
-------- Reading 1 0.0.94.91.11.255 Ch. 0 Identifiers for India
Index: 1 Value: 30 2E 30 2E 39 34 2E 39 31 2E 31 31 2E 32 35 35
Attribute2 is not readable.
-------- Reading 1 0.0.94.91.12.255 Ch. 0 Identifiers for India
Index: 1 Value: 30 2E 30 2E 39 34 2E 39 31 2E 31 32 2E 32 35 35
Attribute2 is not readable.
-------- Reading 3 0.0.94.91.14.255 Ch. 0 Identifiers for India
Index: 1 Value: 30 2E 30 2E 39 34 2E 39 31 2E 31 34 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 1 0.0.94.91.18.255 Ch. 0 Identifiers for India
Index: 1 Value: 30 2E 30 2E 39 34 2E 39 31 2E 31 38 2E 32 35 35
Attribute2 is not readable.
-------- Reading 1 0.0.96.1.0.255 Ch. 0 Device ID 1, manufacturing number
Index: 1 Value: 30 2E 30 2E 39 36 2E 31 2E 30 2E 32 35 35
Index: 2 Value: SMR01-1117-0020
-------- Reading 1 0.0.96.1.1.255 Ch. 0 Device ID #2
Index: 1 Value: 30 2E 30 2E 39 36 2E 31 2E 31 2E 32 35 35
Attribute2 is not readable.
-------- Reading 1 0.0.96.1.2.255 Ch. 0 Device ID #3
Index: 1 Value: 30 2E 30 2E 39 36 2E 31 2E 32 2E 32 35 35
Attribute2 is not readable.
-------- Reading 1 0.0.96.1.4.255 Ch. 0 Device ID #5
Index: 1 Value: 30 2E 30 2E 39 36 2E 31 2E 34 2E 32 35 35
Attribute2 is not readable.
-------- Reading 1 0.0.96.2.0.255 Ch. 0 No. of configuration program changes
Index: 1 Value: 30 2E 30 2E 39 36 2E 32 2E 30 2E 32 35 35
Attribute2 is not readable.
-------- Reading 70 0.0.96.3.10.255 Ch. 0 Disconnect control
Index: 1 Value: 30 2E 30 2E 39 36 2E 33 2E 31 30 2E 32 35 35
Attribute2 is not readable.
Attribute3 is not readable.
Attribute4 is not readable.
-------- Reading 4 0.0.96.11.1.255 Ch. 0 Event code #2
Index: 1 Value: 30 2E 30 2E 39 36 2E 31 31 2E 31 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
Attribute4 is not readable.
Attribute5 is not readable.
-------- Reading 4 0.0.96.11.2.255 Ch. 0 Event code #3
Index: 1 Value: 30 2E 30 2E 39 36 2E 31 31 2E 32 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
Attribute4 is not readable.
Attribute5 is not readable.
-------- Reading 4 0.0.96.11.3.255 Ch. 0 Event code #4
Index: 1 Value: 30 2E 30 2E 39 36 2E 31 31 2E 33 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
Attribute4 is not readable.
Attribute5 is not readable.
-------- Reading 4 0.0.96.11.4.255 Ch. 0 Event code #5
Index: 1 Value: 30 2E 30 2E 39 36 2E 31 31 2E 34 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
Attribute4 is not readable.
Attribute5 is not readable.
-------- Reading 4 0.0.96.11.5.255 Ch. 0 Event code #6
Index: 1 Value: 30 2E 30 2E 39 36 2E 31 31 2E 35 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
Attribute4 is not readable.
Attribute5 is not readable.
-------- Reading 4 0.0.96.11.6.255 Ch. 0 Event code #7
Index: 1 Value: 30 2E 30 2E 39 36 2E 31 31 2E 36 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
Attribute4 is not readable.
Attribute5 is not readable.
-------- Reading 1 1.0.0.2.0.255 Ch. 0 Active firmware identifier
Index: 1 Value: 31 2E 30 2E 30 2E 32 2E 30 2E 32 35 35
Attribute2 is not readable.
-------- Reading 1 1.0.0.8.0.255 Ch. 0 Measurement period 1, for averaging scheme 1
Index: 1 Value: 31 2E 30 2E 30 2E 38 2E 30 2E 32 35 35
Attribute2 is not readable.
-------- Reading 1 1.0.0.8.4.255 Ch. 0 Recording interval 1, for load profile
Index: 1 Value: 31 2E 30 2E 30 2E 38 2E 34 2E 32 35 35
Attribute2 is not readable.
-------- Reading 1 1.0.0.8.5.255 Ch. 0 Recording interval 2, for load profile
Index: 1 Value: 31 2E 30 2E 30 2E 38 2E 35 2E 32 35 35
Attribute2 is not readable.
-------- Reading 4 1.0.1.6.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Max. 1 Rate 0 (0 is total)
Index: 1 Value: 31 2E 30 2E 31 2E 36 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
Attribute4 is not readable.
Attribute5 is not readable.
-------- Reading 3 1.0.1.7.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Inst. value
Index: 1 Value: 31 2E 30 2E 31 2E 37 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 3 1.0.1.8.0.255 Ch. 0 Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0 (0 is total)
Index: 1 Value: 31 2E 30 2E 31 2E 38 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 3 1.0.2.8.0.255 Ch. 0 Sum Li Active power- (QII+QIII) Time integral 1 Rate 0 (0 is total)
Index: 1 Value: 31 2E 30 2E 32 2E 38 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 3 1.0.3.7.0.255 Ch. 0 Sum Li Reactive power+ (QI+QII) Inst. value
Index: 1 Value: 31 2E 30 2E 33 2E 37 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 4 1.0.9.6.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Max. 1 Rate 0 (0 is total)
Index: 1 Value: 31 2E 30 2E 39 2E 36 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
Attribute4 is not readable.
Attribute5 is not readable.
-------- Reading 3 1.0.9.7.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Inst. value
Index: 1 Value: 31 2E 30 2E 39 2E 37 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 3 1.0.9.8.0.255 Ch. 0 Sum Li Apparent power+ (QI+QIV) Time integral 1 Rate 0 (0 is total)
Index: 1 Value: 31 2E 30 2E 39 2E 38 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 3 1.0.10.8.0.255 Ch. 0 Sum Li Apparent power- (QII+QIII) Time integral 1 Rate 0 (0 is total)
Index: 1 Value: 31 2E 30 2E 31 30 2E 38 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 3 1.0.11.7.0.255 Ch. 0 Current: any phase Inst. value
Index: 1 Value: 31 2E 30 2E 31 31 2E 37 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 3 1.0.12.7.0.255 Ch. 0 Voltage: any phase Inst. value
Index: 1 Value: 31 2E 30 2E 31 32 2E 37 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 3 1.0.13.7.0.255 Ch. 0 Sum Li Power factor Inst. value
Index: 1 Value: 31 2E 30 2E 31 33 2E 37 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 3 1.0.14.7.0.255 Ch. 0 Supply frequency Inst. value
Index: 1 Value: 31 2E 30 2E 31 34 2E 37 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 3 1.0.91.7.0.255 Ch. 0 Lo Current (neutral) Inst. value
Index: 1 Value: 31 2E 30 2E 39 31 2E 37 2E 30 2E 32 35 35
Attribute3 is not readable.
Attribute2 is not readable.
-------- Reading 7 0.0.94.91.10.255 Ch. 0 Identifiers for India
Entries: 1/1
Error! Failed to read first row: Access Error : Device reports a inconsistent Class or object.
Error! Failed to read last day: Access Error : Device reports a inconsistent Class or object.
-------- Reading 7 0.0.99.98.1.255 Ch. 0 Event log #2
Entries: 0/20
-------- Reading 7 0.0.99.98.2.255 Ch. 0 Event log #3
Entries: 0/20
-------- Reading 7 0.0.99.98.3.255 Ch. 0 Event log #4
Entries: 0/10
-------- Reading 7 0.0.99.98.4.255 Ch. 0 Event log #5
Entries: 0/10
-------- Reading 7 0.0.99.98.5.255 Ch. 0 Event log #6
Entries: 0/1
-------- Reading 7 0.0.99.98.6.255 Ch. 0 Event log #7
Entries: 0/10
-------- Reading 7 1.0.94.91.0.255 Ch. 0 Identifiers for India
Entries: 1/1
Error! Failed to read first row: Access Error : Device reports a inconsistent Class or object.
Error! Failed to read last day: Access Error : Device reports a inconsistent Class or object.
-------- Reading 7 1.0.94.91.3.255 Ch. 0 Identifiers for India
Entries: 1/1
Error! Failed to read first row: Access Error : Device reports a inconsistent Class or object.
Error! Failed to read last day: Access Error : Device reports a inconsistent Class or object.
-------- Reading 7 1.0.94.91.4.255 Ch. 0 Identifiers for India
Entries: 1/1
Error! Failed to read first row: Access Error : Device reports a inconsistent Class or object.
Error! Failed to read last day: Access Error : Device reports a inconsistent Class or object.
-------- Reading 7 1.0.94.91.5.255 Ch. 0 Identifiers for India
Entries: 1/1
Error! Failed to read first row: Access Error : Device reports a inconsistent Class or object.
Error! Failed to read last day: Access Error : Device reports a inconsistent Class or object.
-------- Reading 7 1.0.94.91.6.255 Ch. 0 Identifiers for India
Entries: 1/1
Error! Failed to read first row: Access Error : Device reports a inconsistent Class or object.
Error! Failed to read last day: Access Error : Device reports a inconsistent Class or object.
-------- Reading 7 1.0.94.91.7.255 Ch. 0 Identifiers for India
Entries: 1/1
Error! Failed to read first row: Access Error : Device reports a inconsistent Class or object.
Error! Failed to read last day: Access Error : Device reports a inconsistent Class or object.
-------- Reading 7 1.0.98.1.0.255 Ch. 0 Data of billing period Scheme 1 #1 Unspecified number of most recent billing periods
Entries: 4/13
07 E4 07 01 03 00 00 00 00 80 00 00 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
/00 00:00:00:000000 |
0 |
/00 00:00:00:000000 |
16352 |
0 |
0 |
Error! Failed to read last day: Access Error : Device reports a inconsistent Class or object.
-------- Reading 7 1.0.99.1.0.255 Ch. 0 Load profile with recording period 1 #1
Entries: 1680/1680
Error! Failed to read first row: Access Error : Device reports a inconsistent Class or object.
-------- Reading 7 1.0.99.2.0.255 Ch. 0 Load profile with recording period 2 #1
Entries: 35/35
Error! Failed to read first row: Access Error : Device reports a inconsistent Class or object.
09/06/20 00:00:00:000000 |
0 |
0 |
0 |
0 |
DisconnectRequest
Ended. Press any key to continue.
What am I doing wrong? Please suggest me.
Hi,
Hi,
Your meter is returning IP addresses in the wrong format. Can you read IPv6 setup 0.0.25.7.0.255 attribute index 4 and add trace here. I can check what the meter is returning.
Add only that one reply.
BR,
Mikko