By silent_7, 16 July, 2020 Forums Gurux.Serial Greetings, I am not able to get the server address. I didn't understand this page https://www.gurux.fi/dlmsAddress can you please help me out to covert this on 553 and it's none Auth with the 0x16 Hi, Hi, What meter do you want to read? If 553 is 0x0229 then the server address is 0x94. BR, Mikko last time you converted 963 last time you converted 963 and low auth to 17347, So I tried to do it 4+229= 4229 and it gave me 16937 and it work but i didn't understand Hi, Hi, Check Coding HDLC Address for server. It'll help you to understand how to count it. https://www.gurux.fi/dlmsAddress BR, Mikko Log in or register to post comments
last time you converted 963 last time you converted 963 and low auth to 17347, So I tried to do it 4+229= 4229 and it gave me 16937 and it work but i didn't understand
Hi, Hi, Check Coding HDLC Address for server. It'll help you to understand how to count it. https://www.gurux.fi/dlmsAddress BR, Mikko
Hi,
Hi,
What meter do you want to read? If 553 is 0x0229 then the server address is 0x94.
BR,
Mikko
last time you converted 963
last time you converted 963 and low auth to 17347,
So I tried to do it 4+229= 4229 and it gave me 16937 and it work but i didn't understand
Hi,
Hi,
Check Coding HDLC Address for server. It'll help you to understand how to count it.
https://www.gurux.fi/dlmsAddress
BR,
Mikko