I found an inconsistent behavior of Gurux DLMS Director while writing a value to a meter.
It is a Data Class where the Value attribute have type OCTET-STRING[12]
If I read the value, the meter answer with something like this:
09 0C xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx which is correct.
If I write the value, the Gurux DLMS director generates something like this:
0A 0C xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx
Then, the request is rejected because the received type (VISIBLE-STRING) is different than meter type (OCTET-STRING).
I understand that behavior of DLMS director is incorrect, if the type of the attribute is OCTET-STRING, DLMS director must create the request with the same type not with a different one.
Hi,
Hi,
This is fixed. New version is released on 4th June.
BR,
Mikko