This error is received because you have data column in your profile generic table that is not found in the device. Usually reason for this is that your device is not correctly configured.
I just heard that there has been problem in SoufceForge.net.
If you click "Download Now" button, it did not download the latest version.
Latest version is 1.0.0.87.
Problem solved. In Profile Generic table (OBIS: 1.0.94.91.3.255) you have added column (OBIS: 0.0.96.7.0.255) with type Register.
The problem is, that you do not have Register Interface with that OBIS code in your EM.
You have Data Interface with OBIS Code 0.0.96.7.0.255.
So you must change Profile generic column's Interface type from Register to Data.
Your EM is configured wrong. This has happened when you have selected columns to Profile Generic. Try to make this again or remove OBIS code 0.0.96.7.0.255 from columns.
As instructed we have deleted the OBIS code 0.0.96.7.0.255 and now we are getting other errors which I have mailed to your mail ID. Also log file is sent
For some reason I missed this. Sorry. You should configure the electricity meter.
I believe that you have received configuration program from the manufacturer.
At this point DLMSDirector is not supporting write.
We have plans to add write functionality for the data and register interfaces quite soon. Profile Generics (Tables) we are add this support later on.
I am using Gurux/Cosem DLMS director to read a meter device Actaris SL7000, but the problem is that I don't get any data of the measuring, only the Logical Name.
How do I do to read the current, power, voltage, etc?.
Hi Mikko,
We are facing some issues with reading m-bus meters through dlms using m bus client object.
Our requirement is to connect the Hydrus m bus water meter to Iskra AM550 mode, (4 mbus meters can be connected and for each m- bus meters 8 registers can be configured).
The problem we are facing is adding the registers (M bus DIF/VIF. The capture definition object is showing some extra fields to be filled Data, and Type other than value information and data information field in the GuruX Mbus capture definition screen.
The following are the water meter objects we try to add
DIF VIF
0C 13
0B 3B
02 5A
When we try to add these objects its showing the below error. Please clarify how we can add these objects. What is the Data and type filed in the object window? Kindly help us, to add these objects using gurux
Re: Error reading through Director
Hi,
This error is received because you have data column in your profile generic table that is not found in the device. Usually reason for this is that your device is not correctly configured.
Best Regards,
Mikko
Thanks for the prompt
Thanks for the prompt reply.
Do you mean configuring device through Director or changing configuration in meter?
How to configure the device properly?
Thanks
Re: Error reading through Director
Hi,
I believe that your device is not correctly configurated. After your device is working right, you should be able to read device.
Best Regards,
Mikko
Hi Mikko, I have sent you
Hi Mikko,
I have sent you the screen shots of the errors received and Configuration details on your mail ID
Regards
Mobineers
New version published
Hi,
We have published new version. We have change "Profile Generic object not found." error so that it will show Logical name of the missing object.
I hope that this will help you.
If you still have problems, please select "View Log" from Tools menu and send the log file to me.
Happy Coding,
Mikko
We are using new version
We are using new version only. Also the same meter is running ok on other API provided by kalkitech.
Can we send you GSM dialup number for the meter for testing.
Your comments are awaited
Your comments are awaited
EMCO problem
Hi,
First Í need the log file. If there are nothing strange, then we can try to make connection to your device. But first, send the log file to me.
Best Regards,
Mikko
Hi, As instructed by you we
Hi,
As instructed by you we tried locating the log file
Tools--->Viw Log
We are getting error message:
The System cannot find the file specified
Regards
Newest version
Hi,
I just heard that there has been problem in SoufceForge.net.
If you click "Download Now" button, it did not download the latest version.
Latest version is 1.0.0.87.
Are you sure that you have the latest version?
Best Regards,
Mikko
Please find Log file
Data is added to log file.
Hui, I have also mailed you
Hui,
I have also mailed you teh above log filealong with the erroe on your mail id
Regards
Thanks from the log.
Hi,
We will start study this tomorrow morning. You will hear us as soon as we find something.
Best Regards,
Mikko
Problem solved
Hi,
Problem solved. In Profile Generic table (OBIS: 1.0.94.91.3.255) you have added column (OBIS: 0.0.96.7.0.255) with type Register.
The problem is, that you do not have Register Interface with that OBIS code in your EM.
You have Data Interface with OBIS Code 0.0.96.7.0.255.
So you must change Profile generic column's Interface type from Register to Data.
Best Regards,
Mikko
Hi, How to change Profile
Hi,
How to change Profile generic column's Interface type from Register to Data.
Please explain
Regards
This error is coming at the
This error is coming at the time the application is trying to capture OBIS codes from meters. How can we stop that, please help
EM is wrong configured
Hi,
Your EM is configured wrong. This has happened when you have selected columns to Profile Generic. Try to make this again or remove OBIS code 0.0.96.7.0.255 from columns.
Best Regards,
Mikko
Hi, As instructed we have
Hi,
As instructed we have deleted the OBIS code 0.0.96.7.0.255 and now we are getting other errors which I have mailed to your mail ID. Also log file is sent
Regards
Mobineers
Info received
Hi,
I have received your mail of errors and the log file. We will analyze those and you will hear from us as soon as we find out something.
Best Regards,
Mikko
We are still waiting for your
We are still waiting for your response.
Sorry slow answer
Hi,
For some reason I missed this. Sorry. You should configure the electricity meter.
I believe that you have received configuration program from the manufacturer.
At this point DLMSDirector is not supporting write.
We have plans to add write functionality for the data and register interfaces quite soon. Profile Generics (Tables) we are add this support later on.
Best Regards,
Mikko
EMCO Meter
Hi,
We updated new version from GXDLMSDirector where we have made few bug fixes.
One bug fix probably fixed your problem.
If not, please, let me know.
BR,
Mikko
I can't read the measuring from dlms Actaris SL7000
Hi
I need some help about that.
I am using Gurux/Cosem DLMS director to read a meter device Actaris SL7000, but the problem is that I don't get any data of the measuring, only the Logical Name.
How do I do to read the current, power, voltage, etc?.
Actaris SL7000
Hi,
You must change Authentication from None to Low.
Actaris returns only Logical name with Low authentication.
BR,
Mikko
Hi Mikko,
Hi Mikko,
We are facing some issues with reading m-bus meters through dlms using m bus client object.
Our requirement is to connect the Hydrus m bus water meter to Iskra AM550 mode, (4 mbus meters can be connected and for each m- bus meters 8 registers can be configured).
The problem we are facing is adding the registers (M bus DIF/VIF. The capture definition object is showing some extra fields to be filled Data, and Type other than value information and data information field in the GuruX Mbus capture definition screen.
The following are the water meter objects we try to add
DIF VIF
0C 13
0B 3B
02 5A
When we try to add these objects its showing the below error. Please clarify how we can add these objects. What is the Data and type filed in the object window? Kindly help us, to add these objects using gurux
Picture attached for your reference